Hemodynamic comparison of CoreValve and SAPIEN-XT TAVI valves in Japanese patients
Koki Shishido1, Futoshi Yamanaka2, Tomoki Ochiai2
1Department of Cardiology, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura, 247-8533, Japan. koki10192002@yahoo.co.jp.
Abstract:
Transcatheter aortic valve implantation (TAVI) is a viable treatment option for high-risk patients with severe aortic stenosis. In Japan, TAVI can be performed using first-generation self-expandable Medtronic CoreValve or balloon-expandable Edwards SAPIEN-XT from 2012. Since the durability and hemodynamic outcomes after transcatheter heart valve (THV) implantation in Japanese patients have not been clearly elucidated, we assessed serial changes in post-TAVI THV performances over a-3-year period by transthoracic echocardiography (TTE). From January 2012 to September 2014, among 83 patients with severe aortic stenosis, 26 underwent TAVI with CoreValve and 57 underwent TAVI with SAPIEN-XT. We assessed the serial changes in first post-implant (FPI) and 3-year post procedure THV hemodynamics by TTE. Valve performance was evaluated by serial assessment of aortic valve mean pressure gradient (PG) and aortic valve area (AVA) assessments. Three-year clinical outcomes were compared between the patients with CoreValve and those with SAPIEN-XT. Seventeen patients with CoreValve and 34 patients with SAPIEN-XT had FPI and 3-year TTEs. The AVA decreased significantly from FPI to 3-year follow-up among patients with SAPIEN-XT, but not among patients with CoreValve. The mean aortic PG decreased significantly from FPI to the 3-year follow-up point among patients with CoreValve; however, it was not significantly different from those with SAPIEN-XT. The absolute change in mean PG from FPI to the 3-year follow-up point decreased significantly among those with CoreValve compared to those with SAPIEN-XT. Clinical outcomes after TAVI were similar for both devices at 3-years after TAVI. In this study, long-term clinical outcomes for CoreValve and SAPIEN XT were similar. The 3-year THV performance of both devices was maintained after TAVI. Serial change in mean aortic PGs for CoreValve decreases significantly from FPI to the 3-year follow-up point compared to that for SAPIEN-XT.
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits