Related Experiment Video
Updated: Jan 26, 2026

Sample Preparation for Probe Electrospray Ionization Mass Spectrometry
Published on: February 19, 2020
Identification of phenobarbital and other barbiturates in forensic drug screening using positive electrospray
Lars Jakobsen Høj1, Christian Brinch Mollerup1, Brian Schou Rasmussen1
1Department of Forensic Medicine, University of Copenhagen, Frederik V's vej 11, 3. Floor, 2100, Copenhagen Ø, Denmark.
Abstract:
Comprehensive drug-screening performed by liquid chromatography-high resolution mass spectrometry (LC-HRMS) enables identification of hundreds to thousands of drug compounds in a single analysis. Forensic drug screening is generally performed with positive electrospray ionization (ESI+ ), targeting basic drugs; however, a few toxicologically important drugs such as barbiturates, may require analysis by negative ESI. In this work, screening targets for barbiturates were determined using our LC-HRMS screening with ESI+ . For several years, our forensic whole blood samples have been analyzed using the LC-HRMS-ESI+ screening in parallel with a multi-target LC-MS/MS-ESI- method. From 2014 to 2018, 23 samples were positive for phenobarbital (0.5-81 mg/kg). Retrospective data analysis of 4816 blood samples (15 positive) revealed several potential screening targets for phenobarbital. The targets were tentatively identified by exact mass and isotopic pattern as uncommon adducts of phenobarbital and as a decomposition product of phenobarbital N-glucoside (C17 H24 N2 O7 ). Analysis of a test set containing eight positive (0.5-65 mg/kg phenobarbital) and 31 negative samples supported the use of the observed target m/z 323.0614 at 5.14 minutes, corresponding to the [M + HCOONa+Na]+ adduct of phenobarbital. The [M + HCOONa+Na]+ adduct was confirmed as a screening target for common barbiturates, by analysis of barbiturate reference standards in ESI+ /ESI- . The [M + HCOONa+Na]+ adduct allowed retrospective analysis with 91% sensitivity (n = 23) and 100% specificity (n = 4855) for phenobarbital in our existing LC-HRMS-ESI+ screening. The two negative results were the two whole-blood samples with the lowest phenobarbital concentration (<1.8 mg/kg). Thus, a specialized screening is not necessary and use of this adduct likely enables screening for other barbiturates.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
High-Resolution Mass Spectrometry (HRMS)
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Sedatives and Hypnotics Drugs: Barbiturates