Related Experiment Video
Updated: Jan 26, 2026

The Ingestion of Fluorescent, Magnetic Nanoparticles for Determining Fluid-uptake Abilities in Insects
Published on: December 20, 2017
Ability of mini-fluid challenge to predict fluid responsiveness in obese patients undergoing surgery in the prone
Achmet Ali1, Yeser Dorman1, Taner Abdullah2
1Department of Anesthesiology and Reanimation, Istanbul Medical Faculty, Istanbul University, Istanbul, Turkey.
Background:
Pulse pressure variation (PPV) and stroke volume variation (SVV) can predict fluid responsiveness effectively. However, high Body Mass Index (BMI) can restrict their use due to changes in respiratory system compliance (CS), intra-abdominal pressure, and stroke volume (SV) in the prone position. Therefore, we aimed to investigate the effectiveness of mini-fluid challenge (MFC) in predicting fluid responsiveness in obese (BMI ≥30 kg/m2) patients in the prone position.
Methods:
A total of 33 patients undergoing neurosurgery were included. After standardized anesthesia induction, patients' PPV, SVV, stroke volume index (SVI) and CS values were recorded in the prone position (T1), after the infusion of 100 mL of crystalloid named as MFC (T2) and after fluid loading was completed with additional 400 mL of crystalloid. Patients whose SVI increased more than 15% after the fluid loading were defined as volume responders.
Results:
Fifteen (45%) patients were responders to 500 mL fluid loading. After the 100 mL fluid load, a higher percentage increase in SVI was observed among responders (P<0.001), with values of 6.6% (6.2-8.6%) and 3.5% (1.7-4.8%) in responders and non-responders, respectively. Areas under the receiver operating characteristic curves of MFC, PPV, and SVV were 0.967 (95% CI: 0.838-0.999), 0.683 (95% CI: 0.499-0.834), and 0.709 (95% CI: 0.526-0.853), respectively. The area under the curve of MFC was significantly higher than that of PPV (P=0.003) and SVV (P=0.005).
Conclusions:
The increase in SVI after a rapid infusion of 100 mL crystalloid could predict fluid responsiveness in patients with BMI ≥30 kg/m2 in the prone position.
More Related Videos
07:59Bedside Ultrasound for Guiding Fluid Removal in Patients with Pulmonary Edema: The Reverse-FALLS Protocol
Published on: July 28, 2018
07:14A Quantitative Sensory Testing Paradigm to Obtain Measures of Pain Processing in Patients Undergoing Breast Cancer Surgery
Published on: January 18, 2018
Related Concept Videos
The Fluid Mosaic Model
Accelerating Fluids
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid:
Cerebrospinal Fluid
CSF Production
CSF is produced mainly in the choroid plexus, a network of capillaries and ependymal cells located within the ventricular system of the brain....
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific...
Characteristics of Fluids
Fluids, which include both liquids and gases, are substances that deform continuously under shearing stress. For example, water and oil are liquids with molecules that can...
Characteristics of Fluids