Related Experiment Video
Updated: Jan 26, 2026

Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
Dual-Source Computed Tomography of the Chest in Blunt Thoracic Trauma: Reduced Aortic Motion Using a Novel Temporal
Teresa Liang1, Patrick D McLaughlin1, James P Nugent1
1Department of Radiology, Vancouver General Hospital, Vancouver, BC, Canada.
Purpose:
The purpose of this study was to evaluate the clinical utility of temporal resolution optimization (TR-Opt), a computed tomography (CT) postprocessing technique, in reducing aortic motion artifacts in blunt thoracic trauma patients.
Materials And Methods:
This was an IRB-approved study of 61 patients with blunt thoracic trauma carried out between February 18 and September 6, 2014; the patients had been imaged using a standardized dual-source high-pitch (DSHP) CT protocol. Image raw data were retrospectively postprocessed using the TR-Opt algorithm (DSHP-TR-Opt) and compared with conventional images (DSHP). Diagnostic ability to confidently identify and exclude potential injuries and qualitative aortic motion artifacts using a 5-point Likert scale (1=absence of motion artifacts; 5=severe motion artifact) was graded by 2 readers at multiple thoracic locations. Signal-to-noise and contrast-to-noise ratios were generated as quantitative indices of image quality.
Results:
Motion artifacts degrading interpretation and limiting diagnosis of aortic injuries were present in 45% (442/976) of the assessed regions on DSHP. TR-Opt algorithm eliminated motion artifacts in 85% of the motion-degraded areas (375/442), leaving persistent motion artifacts in only 15% (67/442). Motion artifacts were most improved at the interventricular septum (1±1 vs. 3±1), aortic valve (2±1 vs. 4±1.5), and ascending aorta (1±1 vs. 3±2, P<0.005). Mean aorta noise (NAo) was 41.7% higher in the DSHP-TR-Opt images (26.5 vs. 18.7 HU, P<0.0001).
Conclusions:
Temporal resolution optimized reconstruction is a raw data-based CT postprocessing technique that can be used to remove the majority of thoracic aortic motion artifacts that commonly degrade interpretation when imaging blunt thoracic trauma patients.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
Imaging Studies III: Computed Tomography
Methods of reducing fever
Pharmacological Methods of Reducing Fever:
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
Flail Chest-I
Flail chest is a severe and potentially life-threatening condition characterized by the fracture of three or more adjacent ribs in multiple places. It is most commonly caused by direct impacts and trauma, such as motor vehicle accidents or injuries from a steering wheel impact. It can also occur due to falls in elderly individuals with osteoporosis, or assaults involving sharp objects.
Pathophysiology
The pathophysiology of flail chest is complex, involving fractures of...

