Related Experiment Video
Updated: Jan 26, 2026

A Standardized Liquid Biopsy Preanalytical Protocol for Downstream Circulating-Free DNA Applications
Published on: September 16, 2022
Computed-tomography-guided biopsy in suspected spondylodiscitis: Single-center experience including 201 biopsy
Derya Özmen1, Neriman Özkan2, Nika Guberina1
1Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen.
Abstract:
Our propose is to evaluate CT-guided biopsies in suspected spondylodiscitis with respect to puncture site, microbiology findings, histopathology findings and impact on antibiotic therapy. 86 CT-guided spine interventions in suspected spondylodiscitis comprising 201 biopsy procedures were analyzed. Medical records of all patients were screened for microbiology and histopathology reports as well as date, duration and kind of antibiotic therapy. Statistical analyses included calculation of Chi2-tests and logistic regression analyses. Locations of biopsies were intervertebral disc (48.3%), paravertebral soft-tissue (38.3%) and vertebral body (10.9%). Positive microbiological findings were found altogether in 33.8% of cases, positive histopathological findings in 53.6%. Significant associations between positive microbiological findings, positive histopathological findings and antibiotic therapy, respectively, were found. Location of biopsies did not significantly influence rate of positive findings. From the variables age, white blood cell count, serum creatinine and puncture site, none were found to be an independent predictor for a positive microbiological result. We concluded that CT-guided biopsy of intervertebral disc and paravertebral soft tissue yields positive microbiologic findings in a significant proportion of cases. Puncture site is not associated with positive results of microbiology or histopathology.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Lattice Centering and Coordination Number
Types of Unit Cells
Imagine taking a large number of identical...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Center of Gravity
Center of Gravity
To determine its location, the principle of moments can be utilized by dividing the object into...

