Related Experiment Video
Updated: Jan 26, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
A clinical evaluation of two central venous catheter stabilization systems
Tarja J Karpanen1, Anna L Casey2, Tony Whitehouse3
1Department of Clinical Microbiology, University Hospitals Birmingham NHS Foundation Trust, Queen Elizabeth Hospital, Mindelsohn Way, Edgbaston, Birmingham, B15 2WB, UK.
Background:
Central venous catheters (CVCs) are commonly secured with sutures which are associated with microbial colonization and infection. We report a comparison of a suture-free system with standard sutures for securing short-term CVC in an international multicentre, prospective, randomized, non-blinded, observational feasibility study. Consented critical care patients who had a CVC inserted as part of their clinical management were randomized to receive either sutures or the suture-free system to secure their CVC. The main outcome measures were CVC migration (daily measurement of catheter movement) and unplanned catheter removals.
Results:
The per cent of unplanned CVC removal in the two study groups was 2% (suture group 2 out of 86 patients) and 6% (suture-free group 5 out of 85 patients). Both securement methods were well tolerated in terms of skin irritation. The time and ease of application and removal of either securement systems were not rated significantly different. There was also no significant difference in CVC migration between the two securement systems in exploratory univariate and multivariate analyses. Overall, 42% (36 out of 86) of the CVC secured with sutures and 56% (48 out of 85) of the CVC secured with the suture-free securement system had CVC migration of ≥ 2 mm.
Conclusions:
The two securement systems performed similarly in terms of CVC migration and unplanned removal of CVC; however, the feasibility study was not powered to detect statistically significant differences in these two parameters.
Trial Registration:
ISRCTN, ISRCTN13939744. Registered 9 July 2015, http://www.isrctn.com/ISRCTN13939744 .
More Related Videos
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
Nuclear Stability
To hold positively charged protons together...
RNA Stability
The Central Dogma
Measures of Central Tendency