Related Experiment Video
Updated: Jan 26, 2026

Intraoperative Ultrasound in Spinal Surgery
Published on: August 17, 2022
Automated Ambulatory Blood Pressure Measurements and Intraoperative Hypotension in Patients Having Noncardiac Surgery
Bernd Saugel1, Philip C Reese, Daniel I Sessler
1From the Department of Anesthesiology, Center of Anesthesiology and Intensive Care Medicine (B.S., P.C.R., C.B., J.Y.N., S.S.) the Department of Medical Biometry and Epidemiology (H.O.P.), University Medical Center Hamburg-Eppendorf, Hamburg, Germany the Department of Outcomes Research, Anesthesiology Institute, Cleveland Clinic, Cleveland, Ohio (D.I.S.) the Department of Anesthesiology and Intensive Care Medicine, University Medical Center Rostock, Rostock, Germany (D.A.R.).
Background:
Normal blood pressure varies among individuals and over the circadian cycle. Preinduction blood pressure may not be representative of a patient's normal blood pressure profile and cannot give an indication of a patient's usual range of blood pressures. This study therefore aimed to determine the relationship between ambulatory mean arterial pressure and preinduction, postinduction, and intraoperative mean arterial pressures.
Methods:
Ambulatory (automated oscillometric measurements at 30-min intervals) and preinduction, postinduction, and intraoperative mean arterial pressures (1-min intervals) were prospectively measured and compared in 370 American Society of Anesthesiology physical status classification I or II patients aged 40 to 65 yr having elective noncardiac surgery with general anesthesia.
Results:
There was only a weak correlation between the first preinduction and mean daytime mean arterial pressure (r = 0.429, P < 0.001). The difference between the first preinduction and mean daytime mean arterial pressure varied considerably among individuals. In about two thirds of the patients, the lowest postinduction and intraoperative mean arterial pressures were lower than the lowest nighttime mean arterial pressure. The difference between the lowest nighttime mean arterial pressure and a mean arterial pressure of 65 mmHg varied considerably among individuals. The lowest nighttime mean arterial pressure was higher than 65 mmHg in 263 patients (71%).
Conclusions:
Preinduction mean arterial pressure cannot be used as a surrogate for the normal daytime mean arterial pressure. The lowest postinduction and intraoperative mean arterial pressures are lower than the lowest nighttime mean arterial pressure in most patients.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Observational Studies
There are three types of observational studies – Prospective, retrospective, and cross-sectional.
Prospective Study
Prospective studies, also known as longitudinal or cohort studies, are carried out by collecting future data from groups sharing similar characteristics. One...