Related Experiment Video
Updated: Jan 26, 2026

Author Spotlight: Evaluating the Adjuvant Efficacy and Safety of Angong Niuhuang Pill in Viral Encephalitis Treatment
Published on: April 19, 2024
Narrow-Band Imaging for Detection of Neoplasia at Colonoscopy: A Meta-analysis of Data From Individual Patients in
Nathan S S Atkinson1, Shara Ket2, Paul Bassett3
1Translational Gastroenterology Unit, John Radcliffe Hospital, University of Oxford, Oxford, UK; Oxford National Institute for Health Research Biomedical Research Centre, Oxford, UK; Department of Gastroenterology, Waitemata District Health Board, Auckland, New Zealand.
Background & Aims:
Adenoma detection rate (ADR) is an important quality assurance measure for colonoscopy. Some studies suggest that narrow-band imaging (NBI) may be more effective at detecting adenomas than white-light endoscopy (WLE) when bowel preparation is optimal. We conducted a meta-analysis of data from individual patients in randomized controlled trials that compared the efficacy of NBI to WLE in detection of adenomas.
Methods:
We searched MEDLINE, EMBASE, and Cochrane Library databases through April 2017 for randomized controlled trials that assessed detection of colon polyps by high-definition WLE vs NBI and from which data on individual patients were available. The primary outcome measure was ADR adjusted for bowel preparation quality. Multilevel regression models were used with patients nested within trials, and trial included as a random effect.
Results:
We collected data from 11 trials, comprising 4491 patients and 6636 polyps detected. Adenomas were detected in 952 of 2251 (42.3%) participants examined by WLE vs 1011 of 2239 (45.2%) participants examined by NBI (unadjusted odds ratio [OR] for detection of adenoma by WLE vs NBI, 1.14; 95% CI, 1.01-1.29; P = .04). NBI outperformed WLE only when bowel preparation was best: adequate preparation OR, 1.07 (95% CI, 0.92-1.24; P = .38) vs best preparation OR, 1.30 (95% CI, 1.04-1.62; P = .02). Second-generation bright NBI had a better ADR than WLE (second-generation NBI OR, 1.28; 95% CI, 1.05-1.56; P = .02), whereas first-generation NBI did not. NBI detected more non-adenomatous polyps than WLE (OR, 1.24; 95% CI, 1.06-1.44; P = .008) and flat polyps than WLE (OR, 1.24; 95% CI, 1.02-1.51; P = .03).
Conclusions:
In a meta-analysis of data from individual patients in randomized controlled trials, we found NBI to have a higher ADR than WLE, and that this effect is greater when bowel preparation is optimal.
More Related Videos
Related Concept Videos
Statistical Software for Data Analysis and Clinical Trials
Band Theory
The energy difference between these bands is known as the band gap.
Conductor, Semiconductor,...
Endoscopic Procedures II: Colonoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Distribution of Stresses in a Narrow Rectangular Beam
Analysis of Population Pharmacokinetic Data