The investigation of fluid flow in cartilage contact gap
JinJing Liao1, David W Smith2, Saeed Miramini1
1Department of Infrastructure Engineering, The University of Melbourne, Victoria, 3010, Australia.
Abstract:
Synovial fluid flow in articular joint capsule plays an important role during mixed mode lubrication. However, the actual fluid flow behaviour during cartilage contact has not been fully understood so far. This is due to the difficulties in measuring the gap permeability using conventional experimental techniques. The problem becomes further complicated with consideration of the cartilage surface roughness. Here a validated numerical study was developed to quantify the gap permeability of lateral synovial fluid flow. Both macro- and micro-scale gap flow models were created based on Darcy's law at the macro-scale and the Navier-stokes equation at the micro-scale. To generate model inputs, the cartilage topography was numerically synthesised based on the experimental measurements of bovine medial tibia cartilage surface roughness using Dektak Stylus Profilers. The experimental results show that the average roughness height Ra is 1.97 μm and root-mean-square roughness height Rq is 2.44 μm, while the correlation lengths of the secondary and tertiary undulations are round 100 μm and 20 μm, respectively. The numerical results indicate that the contact gap height and fluid pressure gradient are two critical parameters which significantly affect the gap permeability. As the contact gap closes, there is a decrease in gap permeability, and most importantly, the gap permeability is also very sensitive to the fluid pressure gradient. Furthermore, with gap closure, the permeability of the contact gap gradually approaches that of the cartilage tissue, at which point the contact gap is functional closed. This occurs at a contact gap height around 1 μm and fluid pressure gradient below 5 × 105 Pa/m in this study.
Related Concept Videos
Steady Flow of a Fluid Stream
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Gap Junctions
Gap Junctions
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
The Fluid Mosaic Model