Related Experiment Video
Updated: Jan 26, 2026

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
The Exeter Short Revision Stem for Cement-in-Cement Femoral Revision: A Five to Twelve Year Review
Adam B Woodbridge1, Matthew J Hubble1, Sarah L Whitehouse2
1Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter Hospital, Exeter, United Kingdom.
Background:
Cement-in-cement femoral revision is a proven technique in revision total hip arthroplasty, with excellent results reported using standard-sized Exeter stems. The Exeter 44/00/125 short revision stem was introduced in 2004 to facilitate cement-in-cement revision. The stem is 25-mm shorter and has a slimmer body than standard stems to facilitate adjustment of depth of insertion and stem version. It is not known if this change in stem size affects its long-term performance. We therefore reviewed the outcome of all Exeter short revision stems used for cement-in-cement revision in our unit, with a minimum of 5 years of follow-up.
Method:
One hundred sixty-six cases were performed between 2004 and 2010. Mean follow-up of surviving patients was 8.1 years (range 5.0-11.7). The fate of all 166 hips were known and included in the survival analysis.
Results:
Median clinical scores improved significantly. Sixteen hips required re-revision (infection 6, loose cup 3, periprosthetic fracture 3, instability 2, stem fracture with chronic infection 1, and pain 1). Kaplan-Meier survival analysis at 10 years revealed 100% survival for aseptic stem loosening, 96.8% survival for stem failure, and 88.9% survival for all causes.
Conclusion:
The Exeter short revision stem performed as well as standard length stems for cement-in-cement revision in this the largest and longest review of their use. Larger registry-based studies may provide additional information on the performance of this stem.
Related Concept Videos
Hydration of Cement
Soundness of Cement
Portland Cement
Fineness of Cement
Direct...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Types of Cement I
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...