Related Experiment Video
Updated: Jan 26, 2026

Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Olecranon Osteotomy Approach for Complex AO-13C Fractures of Distal Humerus: A Prospective Analysis of 24 Cases
R Singh1,2,3, H Singh2, N Kanodia3
1Department of Orthopaedics, Mayo Institute of Medical Sciences, Uttar Pradesh, India.
Abstract:
Introduction: Olecranon osteotomy is well described approach for complex intra-articular distal humeral fractures. In this study, we investigated the usefulness and complications of olecranon osteotomy approach for such fractures. We hypothesise that outcome is comparable in young adults and middle age group and also functional outcome is independent of fracture subtype following surgical fixation. Materials and Methods: Between December 2012 and September 2015, twenty-four adult patients (male: 15, female: 9) having mean age of 41.4 years with closed intra-articular fracture (AO-13C) were surgically managed using olecranon osteotomy approach and were followed-up for a mean of 28.5 months (range: 22-35 months). Functional outcome was measured using Mayo Elbow Performance Score (MEPS) and complications were observed. Statistical analysis was done using Student t-test and Kruskal Wallis test. Results: All fractures united by the end of three months. Mean elbow flexion achieved was 123°, mean extension lag was 9° and mean active arc of motion was 114°. Mean MEPS was 87 (excellent: 8, good: 14, fair: 1 and poor: 1). Post-operative transient ulnar nerve palsy was noted in two cases, heterotopic ossification (HO) was in one case, infection in two cases, implant prominence in five and elbow stiffness in three cases. Motion arc was higher in young adults and MEPS was comparable in both age group. Functional outcome was also dependent on fracture subtype. Conclusion: The olecranon osteotomy approach for distal humerus fractures had good functional outcome with fewer complications. Joint congruity and fixation could easily be assessed intraoperatively.
Related Concept Videos
Bones of the Upper Limb: Humerus
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Holter Monitor: 24-Hour Monitoring
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Protein Complex Assembly
Many viruses self-assemble into a fully functional unit using the infected host cell to...
Protein Complexes with Interchangeable Parts
The SCF ubiquitin ligase is a protein complex of five individual proteins. This complex attaches ubiquitin to other target proteins to mark them for degradation. In order...

