Process Control in Jet Electrochemical Machining of Stainless Steel through Inline Metrology of Current Density

Matin Yahyavi Zanjani1, Matthias Hackert-Oschätzchen2, André Martin3

  • 1Professorship Micromanufacturing Technology, Faculty of Mechanical Engineering, Chemnitz University of Technology, 09107 Chemnitz, Germany. matin.yahyavi-zanjani@mb.tu-chemnitz.de.

Micromachines
|April 21, 2019
PubMed

Related Concept Videos

Current Density01:21

Current Density

The total amount of current flowing through one unit value of a cross-sectional area is referred to as current density. If the current flow is uniform, the amount of current flowing through a conductor is the same at all points along the conductor, even if the conductor area varies. The current density consists of the local magnitude and direction of the charge flow, which varies from point to point. Current density is measured in amperes per meter square, and direction is defined as the net...
5.1K
Boundary Conditions for Current Density01:25

Boundary Conditions for Current Density

Current density becomes discontinuous across an interface of materials with different electrical conductivities. The normal component of the current density is continuous across the boundary.
1.3K
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
672
What is an Electrochemical Gradient?01:26

What is an Electrochemical Gradient?

Adenosine triphosphate, or ATP, is considered the primary energy source in cells. However, energy can also be stored in the electrochemical gradient of an ion across the plasma membrane, which is determined by two factors: its chemical and electrical gradients.
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
127.5K
Free Jet01:14

Free Jet

Free jets describe the flow of liquid exiting a reservoir through an opening into the atmosphere without resistance. The velocity (v) of the liquid jet is derived using Bernoulli's principle and expressed as:
560
Introduction to Statistical Process Control01:15

Introduction to Statistical Process Control

Statistical Process Control (SPC) is a method used to monitor and control quality within processes, particularly in manufacturing and service delivery, by employing statistical methods. SPC aims to distinguish between natural (common cause) variation and variation due to specific changes or events (special cause), allowing for timely improvements and sustained quality. The control chart, a pivotal tool in SPC, visually displays data over time alongside a central line of upper and lower control...
632