A Wearable Compression Device to Normalise Calf Muscle Pump Function in Chronic Venous Insufficiency for Each
Giovanni Mosti1, Hugo Partsch2
1Clinica MD Barbantini, Via del Calcio n.2; 55100 Lucca, Italy.
Background:
For the currently used compression therapy, the applied compression pressure is usually inadequate to exert an effective impact on the veins in different body positions. The aim was to assess the venous ejection fraction achieved by a new compression device which automatically adjusts the interface pressure to body position in an acute experimental setting.
Methods:
A new portable, battery driven compression device providing pressure adjusted to allow for body position, and connected to a less or very stiff calf cuff wrap was tested. In patients with superficial venous incompetence, the ejection fraction (EF) of the calf pump was measured by strain gauge plethysmography. Applied in a random sequence, values achieved without compression, with the two cuffs, and with compression stockings exerting 23-32 mmHg, were compared. The applied compression pressures were simultaneously recorded in the supine and standing positions, and during walking. Comfort was assessed by a visual analogue scale (VAS) with 0 corresponding to very low comfort and 10 to very comfortable.
Results:
In 16 patients with CEAP clinical stage C3-C6, EF without compression was 37%, increasing to 46.9% with stockings, to 64.8% (p < .001) by less stiff and to 75.5% (p < .001) by stiffer wraps. The median interface pressure (supine/standing) was 31/56 mmHg for the less stiff device, 32/68 mmHg for the stiffer device, and 23/26 mmHg for the stockings. The static stiffness index and the walking pressure amplitudes were significantly higher than those generated by the stocking, and the highest values were found with the stiffer wrap material. The device comfort was high both in the supine and standing positions (VAS 8 ± 2).
Conclusions:
The tested devices were comfortable at rest and haemodynamically effective during walking by automatically adjusting compression pressures to body position. They are significantly more effective than elastic stockings in improving EF. The system is able to overcome the problems of fast pressure loss by continuously re-adjusting the compression pressure.
More Related Videos
Related Concept Videos
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Functions of Smooth Muscles
Function of visceral smooth muscles
Visceral smooth muscle is found in the walls of all hollow organs, except the heart, and is a key player in the involuntary movements that drive the functioning of these internal organs. This tissue is arranged in...
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...