The Combined Use of Pleural Fluid Parameters Improves Diagnostic Accuracy in Complicated Pleural Infection/Empyema

Lucía Ferreiro1, Óscar Lado-Baleato2, Juan Suárez-Antelo3

  • 1Servicio de Neumología, Complejo Hospitalario Clínico Universitario de Santiago de Compostela, Grupo Interdisciplinar de Investigación en Neumología. Instituto de Investigaciones Sanitarias de Santiago (IDIS), Santiago de Compostela, A Coruña, España.

Abstract

Related Concept Videos

Pleural Effusion I: Introduction01:25

Pleural Effusion I: Introduction

Pleural effusion is an abnormal fluid accumulation in the pleural cavity, a narrow space between the lungs and the chest wall. It is not a disease per se but rather a symptom or indication of an underlying disease. In normal circumstances, this space contains a small amount of fluid (5 to 15 mL), a lubricant facilitating the non-frictional movement of the pleural surfaces.
There are two main types of pleural effusion: transudative and exudative. They are differentiated using Light's...
4.1K
Pleural Disorders: Types and Brief Description01:30

Pleural Disorders: Types and Brief Description

The pleura is a vital part of the respiratory system. It's a double-layered membrane surrounding the lungs and lining the chest cavity. The two layers of the pleura are:
643
Pleural Effusion II: Symptoms and Management01:28

Pleural Effusion II: Symptoms and Management

Pleural Effusion Overview
A pleural effusion is the abnormal collection of fluid between the parietal and visceral pleura layers of tissue that form the lining of the lungs and chest cavity. It can occur independently or due to surrounding parenchymal diseases, such as infection, malignancy, or inflammatory conditions.
Clinical Manifestations:
706
Improving Translational Accuracy02:07

Improving Translational Accuracy

Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
14.1K
Improving Translational Accuracy02:07

Improving Translational Accuracy

3.6K
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
100.5K