Early silent graft failure in off-pump coronary artery bypass grafting: a computed tomography analysis†
Alicja Zientara1, Laura Rings1, Hans Bruijnen2
1Department of Cardiac Surgery, Triemli Hospital, Zurich, Switzerland.
Objectives:
The purpose was to assess predictors of early silent graft failure prior to discharge by multislice computed tomography in patients after off-pump coronary artery bypass grafting.
Methods:
From January 2017 until April 2018, 192 computed tomographic scans of consecutive asymptomatic patients were performed (seventh postoperative day ± 4 days) and analysed retrospectively. In total, 359 arterial and 278 venous anastomoses were evaluated. Two patient groups (overall patent anastomoses versus at least 1 occluded anastomosis) were compared. Cardiovascular risk factors, collateralization according to Rentrop, grade of native vessel stenosis and intraoperative flow measurements were analysed. Inferential statistics were performed with the Mann-Whitney U-test. Nominal and categorical variables were tested with the Fisher-Freeman-Halton exact test.
Results:
In 33 patients, at least 1 occluded anastomosis could be identified, predominantly in women (P = 0.04). The patency of the arterial anastomoses was 96.4% and 88.9% for the venous anastomoses. In 14 patients with occluded anastomoses, a successful interventional revascularization was performed before discharge. There were significant differences in lower bypass flow [P = 0.02, odds ratio 3.2, 95% confidence interval (CI) 1.7-6.0] and higher pulsatility index (P < 0.001, odds ratio 4.5, 95% CI 2.4-8.5) in the occluded group. A calculated cut-off value identified an increased probability for graft occlusion at a flow under 23 ml/min and a pulsatility index greater than 2.3.
Conclusions:
Early silent graft failure occurred predominantly in venous grafts, with a tendency to female gender. A lower flow rate and a higher pulsatility index were significantly associated with graft occlusion, whereas collateralization and the degree of native vessel stenosis seem to play a tangential role. Fourteen patients had a successful percutaneous revascularization before discharge.
Clinical Trial Registration Number:
NCT03657199.
More Related Videos
09:12Surgical Swine Model of Chronic Cardiac Ischemia Treated by Off-Pump Coronary Artery Bypass Graft Surgery
Published on: March 27, 2018
12:00Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Coronary Artery Disease I: Introduction
Coronary Artery Disease II: Pathophysiology
Imaging Studies III: Computed Tomography
Coronary Artery Disease V: Interprofessional Care
Coronary Artery Disease III: Clinical Manifestations