Related Experiment Video
Updated: Jan 26, 2026

Isolation of Human Mesenchymal Stem Cells and their Cultivation on the Porous Bone Matrix
Published on: February 9, 2015
Biological responses of human bone mesenchymal stem cells to Ti and TiZr implant materials
Lihua Yin1, Yaoren Chang2, Yuanhe You2
1Department of Implant Dentistry, Shanghai Ninth People's Hospital, College of Stomatology, Shanghai JiaoTong University School of Medicine, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology, Shanghai, China.
Background:
Titanium-zirconium alloy (TiZr1317) is a new material used for biological implants. There are several studies on the effects of TiZr implants on the biological characteristics of human bone mesenchymal stem cells (hBMSCs).
Purpose:
The purpose of this study was to investigate the biological responses of hBMSCs to implant holes affected by the physicochemical properties of oral implants (TiSLA , TiSLActive , TiZrSLA , and TiZrSLActive ).
Materials And Methods:
Grade 4 Ti and TiZr (13-17% Zr) substrates were modified by sand-blasted large-grit acid-etched (SLA) or hydrophilic sand-blasted large-grit acid-etched (SLActive), resulting in four types of surface with complex microstructures corresponding to the commercially-available implants SLA, RoxolidSLA, SLActive, and RoxolidSLActive (Institute Straumann AG, Basel, Switzerland). Physicochemical properties were detected and the biological responses of hBMSCs were observed.
Results:
Surface morphology characterization by scanning electron microscopy and atomic force microscopy revealed differences between the four groups. SLActive had higher surface energy/wettability than SLA, indicating that increased surface energy/wettability can promote the absorption of osteogenic proteins and enhance osseointegration. hBMSCs seeded on SLActive substrates exhibited better performance in terms of cell attachment, proliferation and osteoblastic differentiation than cells seeded on SLA.
Conclusion:
Because of their more suitable physicochemical properties, TiSLActive and TiZrSLActive materials demonstrated more pronounced effects on the biological responses of hBMSCs compared with TiSLA and TiZrSLA .
Related Concept Videos
Mesenchymal Stem Cells
Biological Clocks and Seasonal Responses
What is Conservation Biology?
Role of Water in Human Biology
Water's Solvent Properties
Since water is a polar molecule with slightly positive and slightly negative charges, ions and polar molecules can readily dissolve in it. Therefore, it is referred to as a solvent, a...
Adult Stem Cells
Embryonic Stem Cells