Related Experiment Video
Updated: Jan 26, 2026

Role of Diffusion MRI Tractography in Endoscopic Endonasal Skull Base Surgery
Published on: July 5, 2021
Diffusion MRI using two-dimensional single-shot radial imaging (2D ss-rDWI) with variable flip angle and random view
Kyle E Jeong1, Edward W Hsu2, Eun-Kee Jeong3
1Utah Center for Advanced Imaging Research, University of Utah, Salt Lake City, UT, United States of America; Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States of America.
Purpose:
The main objective of this study is to develop a 2D single-shot radial-DWI (2D ss-rDWI) technique to reduce motion artifacts and geometric distortion in DW images.
Method:
A diffusion-preparation module is developed and applied prior to the data acquisition. Because the diffusion-prepared longitudinal magnetization is measured over multiple RF excitations in each shot, 2D ss-rDWI is subject to low signal-to-noise ratio (SNR). We used variable-flip angle (VFA), random view ordering (RVO), and sliding spokes, and compared the performances to constant flip angle (CFA), smooth view ordering (SVO), and identical spoke averaging, respectively. For each technique, we performed numerical simulation and MRI experiments on a fluid phantom as well as in-vivo human brain studies with a 3 T MRI system.
Results:
Using VFA, optimal SNR was acquired for 2D ss-rDWI. Using SVO, the high signal is clustered at specific quadrant in 2D k-space: the first quadrant using high initial flip angle or the last quadrant using the low flip angle. This clustered signal in k-space led to geometric distortion in image space. 2D ss-rDWI using RVO spreads the high signaled spokes over all angular directions and removes the view-order-related distortion. The in-vivo images using 2D ss-rDWI with VFA and RVO show no geometric distortion at the skull base brain, but greatly reduced SNR compared with those using 2D ss-DWEPI.
Conclusion:
2D ss-rDWI is optimized by using VFA with RVO. The resultant DWI using 2D ss-rDWI is insensitive to motion-induced artifacts and geometric distortion. Even with low SNR, it may be useful for DWI of organs limited by severe susceptibility-induced geometric distortion.
Related Concept Videos
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
Diffusion
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)

