Related Experiment Video
Updated: Jan 26, 2026

Occlusion of the Great and Small Saphenous Vein Using Copolymeric Glue Based on N-Butyl Cyanoacrylate and Methacryloxy Sulfolane
Published on: December 9, 2022
The V-Block Occlusion Stent and Sclerotherapy Device for Varicose Vein Treatment: A Retrospective Analysis
Ralf R Kolvenbach1, Steven Elias2, Alex Belinky3
1Vascular Centre Catholic Hospital Group Duesseldorf, Augusta Hospital, Duesseldorf, Federal Republic of Germany.
Background:
The procedure aims to show our results with a novel nontumescent, nonthermal technique to treat varicose veins. The V-block occlusion stent is a minimally invasive device for treating reflux of the great saphenous vein (GSV). It is an office-based procedure that does not require tumescence anesthesia. The V-block stent is a self-expandable device that functions as a vein occluder and blood clot trap. Once the V-block is in place, further treatment of the saphenous vein such as ultrasound-guided sclerotherapy can be performed. The V-block device is intended to eliminate the possibility of forwarding passage of clot and sclerosant (embolization) to the deep and pulmonary circulations.
Methods:
Patients were treated in an outpatient setting with the V-block occluding device. Follow-up was performed using duplex ultrasound to assess occlusion of the saphenous vein as well as the Aberdeen Varicose Vein Questionnaire and Venous Severity Scoring to determine changes in quality of life after the procedure. Patients were followed up at 1 week, 1 month, and 3 months after V-block placement. Duplex scanning was performed to confirm GSV occlusion at all follow-up visits. After deployment of the occlusion stent, a maximum of 2% polidocanol foam was injected with a double barrel syringe which simultaneously evacuated blood from the greater saphenous vein. Follow-up assessment for safety included evaluation of potential complications, device migration, and potential injury at the deployment site.
Results:
Fifty-one symptomatic subjects with documented GSV reflux were enrolled in the study. Complete occlusion of the GSV was achieved in 98% of the patients during the 7-day postprocedural visit. There was no injury at the deployment site. No migration of the V-block device was observed. No deep vein thrombosis or any other complication was recorded. One patient of the 50 patients and 51 procedures experienced an adverse event, phlebitis that resolved under conservative therapy within 4 days with no residual effect. There was a significant improvement in the Aberdeen Vein quality of life measurements and the pain scores. After 3 years, 18 patients were willing to undergo a duplex follow-up examination. The occlusion rate after 3 years was 77.8. There were no device-related complications after this period.
Conclusions:
The study demonstrated a good safety and performance profile without any major adverse events. The primary end point of vein occlusion and obliteration was met.
Related Concept Videos
Varicose Veins I: Introduction
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
Block Diagram Reduction
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
Elements of Block Diagrams
A block diagram typically includes essential elements such as comparators, blocks, and feedback loops. Each of these elements...
Veins of Thorax
The azygos vein, positioned just right of the midline and anterior to the vertebral column, begins at the junction of the right ascending lumbar and subcostal veins, terminating in the superior vena cava. This vein drains blood from the right side of the thoracic wall, thoracic viscera, and posterior abdominal wall.
The...

