Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Modified implantation height of the Sapien3™ transcatheter heart valve
Daniel Wendt1, Sharaf-Eldin Shehada1, Luisa König1
1Department of Thoracic and Cardiovascular Surgery, West German Heart and Vascular Center Essen, Essen, Germany.
Abstract:
Objectives: During transcatheter aortic valve implantation (TAVI), ideal positioning is crucial. The latest-generation balloon expandable Sapien3™ transcatheter heart valve (THV) comes with a marker, which is recommended to be exactly centered at the aortic annular level. We aimed to evaluate a higher "aortic" marker positioning.Material and methods: A total of 119 high-risk patients presenting with aortic stenosis were treated with the Sapien3™ THV. After having placed the THV more "aortic", clinical and hemodynamic data, especially postoperative pacemaker implantation and paravalvular leakages, were evaluated at 30-days according to VARC-2.Results: The Sapien3™ THV was implanted in 92 patients via the transapical, in 13 patients via the transaortic and in 14 patients via the tranfemoral access. Mean age was 80.6 ± 5.7 years. Aortic valve area increased significantly (0.9 ± 0.3 vs. 1.80 ± 0.35cm2, p < .0001) and mean pressure gradients decreased from 41.0 ± 15.0 to 10.4 ± 3.5 mmHg (p < .0001). The majority of patients showed no or mild paravalvular aortic regurgitation (99.1%, 112/113), confirmed by transthoracic echocardiography at 30-days: PVL was absent or trace in 91.2% (103/113), mild in 7.9% (9/113) and moderate in 0.9% (1/113), whereas no patient developed severe PVL. Thirty days mortality was 5.0% (6/119). All patients (n = 113) were in NYHA functional class I or II at 30 days and three patients (2.5%) needed pacemaker implantation.Conclusions: In conclusion, a modified higher "aortic" implantation of the Sapien3™ THV holds promise to further reduce paravalvular leakage as well as permanent pacemaker implantation in TAVI. This trial showed an extremely low postoperative pacemaker implantation rate of 2.5%.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Anatomy of the Heart
Anatomy of the Heart
The heart has three layers: the innermost endocardium, the muscular myocardium, and the outer epicardium, all working together for optimal cardiac function.
Chambers of the Heart
The heart is made up of four...
Mitral Valve Prolapse I: Introduction
Modified Boxplots
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...
Mitral Valve Prolapse II: Assessment and Management