A 0.0014 mm2 150 nW CMOS Temperature Sensor with Nonlinearity Characterization and Calibration for the -60 to +40 °C
Wendi Yang1, Hanjun Jiang2, Zhihua Wang3
1Institute of Microelectronics, Tsinghua University, Beijing 100084, China. yangwd13@mails.tsinghua.edu.cn.
Abstract:
This work presents a complementary metal-oxide-semiconductor (CMOS) ultra-low power temperature sensor chip for cold chain applications with temperatures down to -60 °C. The sensor chip is composed of a temperature-to-current converter to generate a current proportional to the absolute temperature (PTAT), a current controlled oscillator to convert the current to a frequency signal, and a counter as the frequency-to-digital converter. Unlike the conventional linear error calibration method, the nonlinear error of the PTAT current under the low temperature range is fully characterized based on the device model files provided by the foundry. Simulation has been performed, which clearly shows the nonlinear model is much more accurate than the linear model. A nonlinear error calibration method, which requires only two-point calibration, is then proposed. The temperature sensor chip has been designed and fabricated in a 0.13 μm CMOS process, with a total active die area of 0.0014 mm2. The sensor only draws a 140 nA current from a 1.1 V supply, with the key transistors working in the deep subthreshold region. Measurement results show that the proposed nonlinear calibration can decrease the measurement error from -0.9 to +1.1 °C for the measurement range of -60 to +40 °C, in comparison with the error of -1.8 to +5.3 °C using the conventional linear error calibration.
Related Concept Videos
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...