Image quality and radiation dose of renal perfusion CT with low-dose contrast agent: a comparison with conventional
Y Asayama1, A Nishie2, K Ishigami2
1Department of Advanced Imaging and Interventional Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
Aim:
To compare perfusion computed tomography (CT) with reconstructed image from source data using low-dose contrast agent and conventional 320-row CT for the evaluation of renal tumours.
Materials And Methods:
Twenty-eight patients underwent conventional CT (C-CT) and 26 patients underwent perfusion CT with low-dose (40 ml) contrast agent. Image noise, arterial visualisation, the sharpness of the corticomedullary junction (CMJ), and overall image quality were each assessed using a four-point scale. The tumour detection rate for lesions <4 cm (n=66) was also evaluated. Quantitative image parameters including image noise and the contrast-to-noise ratios (CNRs) of the renal artery and CMJ were measured. The volume CT dose index (CTDI), dose-length product (DLP), and size-specific dose estimate (SSDE) were also recorded.
Results:
Although the image noise of perfusion CT was higher than that of C-CT and the overall image quality of perfusion CT was lower than that of C-CT, the arterial visualisation score of perfusion CT was significantly higher than that of C-CT. The CMJ sharpness scores of the two techniques were equivalent. Sensitivity and positive predictive values were also equivalent with respect to tumour detection. The CNRs of both the left and right renal arteries were significantly higher on perfusion CT than on C-CT. The CTDI, DLP, and SSDE of perfusion CT were significantly lower than those of C-CT.
Conclusion:
Perfusion CT using low-dose contrast agent preserved arterial visualisation and the tumour detection rate and achieved a low radiation dose despite image quality degradation and image noise.
More Related Videos
Related Concept Videos
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses