Related Experiment Video
Updated: Jan 25, 2026

Author Spotlight: Advancing Human Cardiac Anatomy Through Multi-Scale Analysis of Hearts
Published on: June 28, 2024
Far-field contributions in multi-electrodes atrial recordings blur distinction between anatomical and functional
Laura Martinez-Mateu1, Lucia Romero1, Javier Saiz1
1Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain.
Background:
Atrial fibrillation (AF) is the most common cardiac arrhythmia and the most important cause of embolic stroke, requiring new technologies for its better understanding and therapies. Recent approaches to map the electrical activity during AF with multi-electrode systems aim at localizing patient-specific ablation targets of reentrant patterns. However, there is a critical need to determine the accuracy of those mapping systems. We performed computer simulations as a numerical approach of systematically evaluating the influence of far-field sources on the electrical recordings and detection of rotors.
Methods:
We constructed 2 computer models of atrial tissue: (i) a 2D sheet model with varying non-active cells area in its center, and (ii) a whole realistic 3D atrial model. Phase maps were built based on the Hilbert transform of the unipolar electrograms recorded by virtual 2D and 3D multi-electrode systems and rotors were tracked through phase singularities detections.
Results:
Analysis of electrograms recorded away from the 2D atrial model shows that the larger the distance between an electrode and the tissue model, the stronger the far-field sources contribution to the electrogram is. Importantly, even if an electrode is positioned in contact with the tissue, the electrogram contains significant contributions from distal sources that blur the distinction between anatomical and functional reentries. Moreover, when mapping the 3D atrial model, remote activity generated false phase singularities at locations without local reentrant excitation patterns.
Conclusions:
Far-field contributions to electrograms during AF reduce the accuracy of detecting and interpreting reentrant activity.
Related Concept Videos
Singularity Functions for Shear
Singularity Functions for Bending Moment
Imaging Studies III: Computed Tomography
Binet's Contribution to Measures of Intelligence
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Standard Electrode Potentials