Patient radiation dose in percutaneous biliary interventions: recommendations for DRLs on the basis of a multicentre
Daniel Schmitz1, Thomas Vogl2, Nour-Eldin Abdelrehim Nour-Eldin2
1Department of Gastroenterology, Oncology and Diabetology, Theresienkrankenhaus and St. Hedwig Hospital, Academic Teaching Hospital of Heidelberg University, Bassermannstr.1, 68165, Mannheim, Germany. d.schmitz@theresienkrankenhaus.de.
Objective:
Percutaneous biliary interventions (PBIs) can be associated with a high patient radiation dose, which can be reduced when national diagnostic reference levels (DRLs) are kept in mind. The aim of this multicentre study was to investigate patient radiation exposure in different percutaneous biliary interventions, in order to recommend national DRLs.
Methods:
A questionnaire asking for the dose area product (DAP) and the fluoroscopy time (FT) in different PBIs with ultrasound- or fluoroscopy-guided bile duct punctures was sent to 200 advanced care hospitals. Recommended national DRLs are set at the 75th percentile of all DAPs.
Results:
Twenty-three facilities (9 interventional radiology depts. and 14 gastroenterology depts.) returned the questionnaire (12%). Five hundred sixty-five PBIs with 19 different interventions were included in the analysis. DAPs (range 4-21,510 cGy·cm2) and FTs (range 0.07-180.33 min) varied substantially depending on the centre and type of PBI. The DAPs of initial PBIs were significantly (p < 0.0001) higher (median 2162 cGy·cm2) than those of follow-up PBIs (median 464 cGy·cm2). There was no significant difference between initial PBIs with ultrasound-guided bile duct puncture (2162 cGy·cm2) and initial PBIs with fluoroscopy-guided bile duct puncture (2132 cGy·cm2) (p = 0.85). FT varied substantially (0.07-180.33 min).
Conclusions:
DAPs and FTs in percutaneous biliary interventions showed substantial variations depending on the centre and the type of PBI. PBI with US-guided bile duct puncture did not reduce DAP, when compared to PBI with fluoroscopy-guided bile duct puncture. National DRLs of 4300 cGy·cm2 for initial PBIs and 1400 cGy·cm2 for follow-up PBIs are recommended.
Key Points:
• DAPs and FTs in percutaneous biliary interventions showed substantial variations depending on the centre and the type of PBI. • PBI with US-guided bile duct puncture did not reduce DAP when compared to PBI with fluoroscopy-guided bile duct puncture. • DRLs of 4300 cGy·cm2for initial PBIs (establishing a transhepatic tract) and 1400 cGy·cm2for follow-up PBIs (transhepatic tract already established) are recommended.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients
Biological Effects of Radiation
Bioavailability Study Design: Single Versus Multiple Dose Studies
Nursing Interventions I: Taxonomy of Nursing Interventions
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
Nursing Interventions II: Selecting and Classifying the Nursing Interventions