Related Experiment Video
Updated: Jan 25, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
PET/CT-Based Response Evaluation in Cancer-a Systematic Review of Design Issues
Oke Gerke1,2, Karen Ehlers3,4, Edith Motschall5
1Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark. oke.gerke@rsyd.dk.
Abstract:
Positron emission tomography/x-ray computed tomography (PET/CT) has long been discussed as a promising modality for response evaluation in cancer. When designing respective clinical trials, several design issues have to be addressed, especially the number/timing of PET/CT scans, the approach for quantifying metabolic activity, and the final translation of measurements into a rule. It is unclear how well these issues have been tackled in quest of an optimised use of PET/CT in response evaluation. Medline via Ovid and Science Citation Index via Web of Science were systematically searched for articles from 2015 on cancer patients scanned with PET/CT before and during/after treatment. Reports were categorised as being either developmental or evaluative, i.e. focusing on either the establishment or the evaluation of a rule discriminating responders from non-responders. Of 124 included papers, 112 (90 %) were accuracy and/or prognostic studies; the remainder were response-curve studies. No randomised controlled trials were found. Most studies were prospective (62 %) and from single centres (85 %); median number of patients was 38.5 (range 5-354). Most (69 %) of the studies employed only one post-baseline scan. Quantification was mainly based on SUVmax (91 %), while change over time was most frequently used to combine measurements into a rule (79 %). Half of the reports were categorised as developmental, the other half evaluative. Most development studies assessed only one element (35/62, 56 %), most frequently the choice of cut-off points (25/62, 40 %). In summary, the majority of studies did not address the essential open issues in establishing PET/CT for response evaluation. Reasonably sized multicentre studies are needed to systematically compare the many different options when using PET/CT for response evaluation.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Design Example: Frog Muscle Response
When the switch connecting the RL circuit is closed, a brief muscle contraction is observed. This is because, at a steady state, the inductor acts like a short...
Group Design
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Ethical Issues
Ethical Concerns in Healthcare:
Random and Systematic Errors