Related Experiment Video
Updated: Jan 25, 2026

Combining Wet and Dry Lab Techniques to Guide the Crystallization of Large Coiled-coil Containing Proteins
Published on: January 6, 2017
Application of radial GRAPPA techniques to single- and multislice dynamic speech MRI using a 16-channel neurovascular
Matthieu Ruthven1, Andreia C Freitas2,3, Redha Boubertakh1,2
1Clinical Physics, Barts Health NHS Trust, St Bartholomew's Hospital, London, United Kingdom.
Purpose:
To investigate: (1) the feasibility of using through-time radial GeneRalized Autocalibrating Partially Parallel Acquisitions (rGRAPPA) and hybrid radial GRAPPA (h-rGRAPPA) in single- and multislice dynamic speech MRI; (2) whether single-slice dynamic speech MRI at a rate of 15 frames per second (fps) or higher and with adequate image quality can be achieved using these radial GRAPPA techniques.
Methods:
Seven healthy adult volunteers were imaged at 3T using a 16-channel neurovascular coil and 2 spoiled gradient echo sequences (radial trajectory, field of view = 192 × 192 mm2 , acquired pixel size = 2.4 × 2.4 mm2 ). One sequence imaged a single slice at 16.8 fps, the other imaged 2 interleaved slices at 7.8 fps per slice. Image sets were reconstructed using rGRAPPA and h-rGRAPPA, and their image quality was compared using the root mean square error, structural similarity index, and visual assessments.
Results:
Image quality deteriorated when fewer than 170 calibration frames were used in the rGRAPPA reconstruction. rGRAPPA image sets demonstrated: (1) in 97% of cases, a similar image quality to h-rGRAPPA image sets reconstructed using a k-space segment size of 4, (2) in 98% of cases, a better image quality than h-rGRAPPA image sets reconstructed using a k-space segment size of 32.
Conclusion:
This study confirmed: (1) the feasibility of using rGRAPPA and h-rGRAPPA in single- and multislice dynamic speech MRI, (2) that single-slice speech imaging at a frame rate higher than 15 fps and with adequate image quality can be achieved using these radial GRAPPA techniques.
Related Concept Videos
Cattell's 16 Personality Factors
In contrast, source traits are the...
Dynamics Of Circular Motion: Applications
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation

