Related Experiment Video
Updated: Jan 25, 2026

Transition of Farm Pigs to Research Pigs using a Designated Checklist followed by Initiation of Clicker Training - a Refinement Initiative
Published on: August 21, 2021
Psychometric testing of a checklist for procedural training of peripheral intravenous insertion
Lisa A Buckley1, Gregory E Gilbert2, Eric B Bauman3
1Ross University School of Medicine, 2300 SW 145th, Suite 200, Miramar, FL 33027 USA.
Background:
Nurses, medical technologists, nuclear medicine technologists, pre-hospital providers, and medical students are a few groups of healthcare learners asked to learn intravenous (IV) cannulation in their training (J Surg Educ. 69:536-43, 2012). Despite the fact that IV cannulation has been taught to several health professions, it is difficult to find a psychometrically validated checklist to guide teaching this skill in the simulated procedural training (Pediatrics 124: 610-9, 2009, J Assoc Vasc Access 21: 196-204, 2016). In the absence of a pragmatic, valid checklist for the initial teaching of peripheral IV skills in the simulation procedural skills lab, this investigation sought to describe the process and create a psychometrically valid checklist.
Methods:
Expert raters used Lawshe's method for identifying valid items from the universe of items for IV insertion. Gwet's AC2 and generalizability (G) theory was used assess inter-rater reliability.
Results:
The literature and in-house IV checklists were examined for steps to inserting a peripheral IV, and the steps were compiled into a survey and sent to experts who rated each item. Of the 37 potential steps, 16 steps were identified as being psychometrically valid. The checklist content validity index was .82. Inter-rater reliability was .94 (95% CI .91-.98). Good inter-rater reliability was confirmed using generalizability theory.
Conclusions:
This study created and provided evidence of content validity and reliability for this checklist using Lawshe's methodology. As such, this method of evaluating a checklist for validity and reliability evidence can be followed for other healthcare checklists. This checklist can be used for teaching IV placement in healthcare students in the simulation procedural training lab.
Related Concept Videos
Porin Insertion in the Outer Mitochondrial Membrane
Three models describe the assembly of porins by the SAM complex and their insertion into the outer membrane. Model 1 suggests that porins are assembled outside the SAM channel as the...
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Insertion of Single-pass Transmembrane Proteins in the RER
Integral transmembrane proteins possess transmembrane and extra membrane domains. The transmembrane domains are primarily made of 20-25 hydrophobic amino acids arranged in a helical secondary confirmation. These...
Insertion of Multi-pass Transmembrane Proteins in the RER
The multipass transmembrane proteins are the type IV integral membrane proteins with multiple topogenic sequences determining their spatial arrangement in the ER membrane. Nearly all multipass proteins lack a cleavable signal sequence and use...
Blind Procedures
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...

