Related Experiment Video
Updated: Jan 25, 2026

A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
Published on: January 13, 2026
Arthroscopic Knotless Remplissage for the Treatment of Hill-Sachs Lesions Using the PASTA Bridge Configuration
Alan M Hirahara1, Wyatt J Andersen1, Kyle Yamashiro2
1Sacramento, California, U.S.A.
Abstract:
Recurrent glenohumeral dislocations can produce Hill-Sachs lesions-bony defects on the humeral head resulting from the humerus hitting the glenoid during dislocations. Some of these lesions can engage on the glenoid during motion, producing instability and potentially affecting the success of a labral repair. The remplissage was developed to address these Hill-Sachs lesions and improve stability. French for "filling," the goal of the remplissage is to fill the Hill-Sachs lesion with the infraspinatus tendon, preventing the margins of the lesion from engaging with the glenoid. Analogous to restoring the rotator cuff footprint during repair, a primary goal of the remplissage is to have the infraspinatus cover the Hill-Sachs lesion. The partial articular supraspinatus tendon avulsion (PASTA) bridge was originally developed for partial-thickness rotator cuff repair in situ, but additional uses have been found in other settings. The PASTA bridge uses a medial row horizontal mattress with a lateral anchor to create a linked construct to effectively distribute force and provide adequate coverage of the lesion. Knotless anchor technology used in this procedure prevents the need for arthroscopic knot tying and potentially damaging knot stacks. This Technical Note describes a remplissage technique using the PASTA bridge configuration to address Hill-Sachs lesions associated with recurrent glenohumeral instability.
More Related Videos
07:24Autologous Microfractured and Purified Adipose Tissue for Arthroscopic Management of Osteochondral Lesions of the Talus
Published on: January 23, 2018
08:11Assessing Forelimb Function after Unilateral Cervical SCI using Novel Tasks: Limb Step-alternation, Postural Instability and Pasta Handling
Published on: September 16, 2013
Related Concept Videos
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Design Example: Strain Gauge Bridge or Wheatstone Bridge
Electron Configuration of Multielectron Atoms
Bridge rectifier
Operationally, the bridge rectifier allows current flow through two of its diodes during each...
Wheatstone Bridge
Thus, for accurate resistance measurements, a...