Application of response surface methodology for silver nanoparticle stir bar sorptive extraction of heavy metals from
Sayyed Hossein Hashemi1, Massoud Kaykhaii2, Ahmad Jamali Keikha3
1Department of Marine Chemistry, Faculty of Marine Science, Chabahar Maritime University, Chabahar, Iran. h_hashemi_85@yahoo.com.
Abstract:
Silver nanoparticles were coated on a glass stir bar by overnight exposure of the bar to the nanoparticle solution, using 3-aminopropyltriethoxysilane as a binding agent and were used for the extraction of heavy metal Fe3+, Cu2+, Pb2+ and Zn2+ cations from water samples after their complexation with the ligand 1-(2-pyridylazo)-2-naphthol, followed by their determination by high performance liquid chromatography. Various parameters affecting the extraction were evaluated by one variable-at-a-time and Box-Behnken design methods and optimized. Six independent variables, the pH and ionic strength of the solution, the Triton X-114 (surfactant) concentration, amount of ligand, and adsorption and desorption times, were coded as A, B, C, D, E and F at three various levels (-1, 0, and 1). The linear ranges of the technique were 0.5-250.0 μg L-1 for all four analytes. Under the optimum conditions, the limits of detection were calculated as 0.08, 0.11, 0.12 and 0.17 μg L-1 for copper, iron, lead and zinc, respectively. The technique was used for the determination of these cations in drinking water samples.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
09:12Optimization of Processing of Tiebangchui with Highland Barley Wine Based on the Box-Behnken Design Combined with the Entropy Method
Published on: May 19, 2023
Related Concept Videos
Response Surface Methodology
The process of RSM involves several key steps:
Design Example: Designing Water Slide
Bernoulli's principle determines the water's velocity along the slide....
Bar Graph
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Design Example: Frog Muscle Response
When the switch connecting the RL circuit is closed, a brief muscle contraction is observed. This is because, at a steady state, the inductor acts like a short...
Design Example: Application of Archimedes' Principle
The volume of seawater displaced by the block is determined by first calculating the block's weight. This is done by multiplying the...