Ex vivo confocal laser scanning microscopy: An innovative method for direct immunofluorescence of cutaneous

Işın S Bağcı1, Rui Aoki1, Sebastian Krammer1

  • 1Department of Dermatology and Allergy, University Hospital, LMU Munich, Munich, Germany.

Related Concept Videos

Immunofluorescence Microscopy01:12

Immunofluorescence Microscopy

A fluorescence microscope uses fluorescent chromophores called fluorochromes, which can absorb energy from a light source and then emit this energy as visible light. Fluorochromes include naturally fluorescent substances (such as chlorophylls) and fluorescent stains that are added to the specimen to create contrast. Dyes such as Texas red and FITC are examples of fluorochromes. Other examples include the nucleic acid dyes 4’,6’-diamidino-2-phenylindole (DAPI), and acridine orange.
13.0K
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
20.1K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
5.4K
Leaky Scanning02:28

Leaky Scanning

During most eukaryotic translation processes, the small 40S ribosome subunit scans an mRNA from its 5' end until it encounters the first start AUG codon. The large 60S ribosomal subunit then joins the smaller one to initiate protein synthesis. The location of the translation initiation is largely determined by the nucleotides near the start codon as there may be multiple translation initiation sites present on the mRNA.  Marilyn Kozak discovered that the sequence RCCAUGG (where R...
5.7K
Microbial Growth Measurement: Direct Methods01:23

Microbial Growth Measurement: Direct Methods

Direct methods for measuring microbial populations in a culture are essential tools in microbiology, providing quantitative data for various applications. Among these, microscopic counts, plate counts, and serial dilution are widely used techniques, each with unique principles and applications.Microscopic CountsMicroscopic counting involves the use of a Petroff-Hausser chamber, a specialized microscope slide with a grid and defined depth. By observing a liquid culture under a microscope,...
1.6K
Directing Effect of Substituents: meta-Directing Groups01:09

Directing Effect of Substituents: meta-Directing Groups

Substituents on the benzene ring that direct an incoming electrophile to undergo substitution at the meta position are called meta directors. All meta directors either have a positive charge on the atom directly bonded to the ring or a partial positive charge. These groups function by withdrawing electrons from the ring through inductive and resonance effects. Consider the carbocation intermediates formed upon the addition of an electrophile on nitrobenzene at the...
5.9K