Related Experiment Video
Updated: Jan 25, 2026

Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents
Published on: October 26, 2016
A retrospective, multicenter analysis of incidents associated with Axios™ lumen-apposing stents
Sergio Bazaga Pérez de Rozas1, Ana Yaiza Carbajo2, Francisco Javier Garcia-Alonso2
1Unidad de Endoscopia Digestiva, Hospital Universitario Río Hortega, España.
Introduction:
there is controversy with regard to the risks associated with lumen-apposing metal stents (LAMSs), with significant variations between available reports.
Objectives:
to describe the types and proportions of complications that arise during the permanence time and removal of Axios™ LAMS. Furthermore, the relationship between patency time, therapeutic target and the presence of complications was also described.
Methods:
a retrospective, multicenter case series study was performed of all patients with an implanted LAMS to access extra-luminal structures during 2017. Only technically successful cases were recorded.
Results:
a total of 179 patients from seven sites (range, 4-68 cases/site) were included in the study, with a mean age of 64.3 years (SD: 15.8; range: 24.6-98.8 years) and 122 (68.2%) were male. Most common indications included encapsulated necrosis (58, 32.4%), pseudocysts (31, 17.3%) and gallbladder drains (26, 14.5%). Complications during LAMS stay were reported in 19 patients (10.9%); stent lumen or gastroduodenal obstruction (8, 4.5%) and bleeding (7, 3.9%) were the most common. LAMS were not removed in 86 (48%) patients due to the following reasons: a permanent stent was used (46, 53.5%), loss to follow-up (18, 20.9%), patient demise (16, 18.6%) and stent migration (6, 7%). Five (5.4%) complications were reported during stent removal, which were three bleeds and two perforations. No association was found between stent duration and complications (p = 0.67).
Conclusion:
complications secondary to LAMS insertion are uncommon but may be serious. This study found no association between complications and stent duration.
Related Concept Videos
Prevalence and Incidence
Prevalence indicates the proportion of individuals in a population who have a specific disease or health...
Types of Reports II: Incident or Occurrence Report
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Qualitative Analysis
For instance, group IV...
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Pedigree Analysis