Related Experiment Video
Updated: Jan 25, 2026

Author Spotlight: Advancements in X-ray CT Tool Chain for Tree Core Analysis
Published on: September 22, 2023
X-Ray Fluorescence Computed Tomography Induced by Photon, Electron, and Proton Beams
Abstract:
X-ray fluorescence CT (XFCT) has shown promise for molecular imaging of gold nanoparticles. To date, XFCT has been induced by kilovoltage photon beams due to the high photoelectric interaction probability. We compare K-shell and L-shell XFCT induced by photon, electron, and proton beams for two phantom sizes. A 2.5 and 5.0-cm diameter phantom with four 5 mm and 10 mm vials, respectively, with gold-solutions of 0.1%-2% by weight were built in TOPAS, a GEANT4-based Monte Carlo simulation tool. The 2.5-cm phantom was imaged with XFCT induced by beams of 7.45×104 81 keV- and 5 MeV-photons, 220 kVp- and 6 MV-photons, 10 MeV- and 100 MeV-electrons, and 100 MeV- and 250 MeV-protons. The doses between each phantom size were equal. First-generation CT geometry with 0.5 mm × 0.5 mm pencil beams with 0.5 mm-translation and 2°-rotation steps over each phantom was modeled. The scattered x-rays were detected on an idealized spherical detector from which the K-shell and L-shell fluorescent x-rays were extracted in 0.5 keV and 0.2 keV bins. XFCT images were generated using iterative reconstruction algorithms. The highest gold sensitivity was seen in the 81 keV-photon K-shell and L-shell images (0.004% and 0.007%) of the 5.0 cm-phantom at 30 mGy. For the 2.5 cm-phantom, the detection limits were 0.006%, 0.62%, and 0.28% for 81 keV-photon K-shell, 100 MeV-electron K-shell, and 100 MeV-proton L-shell images, respectively. The mean imaging dose was approximately 2-3 orders of magnitude higher in electron- and proton-XFCT compared to 81keV-photon XFCT. Our MC study demonstrates that the small-object XFCT imaging achieves the best performance when induced with kilovoltage-photon beams. Due to high imaging doses, electron- and proton-induced XFCT might be feasible for guiding nanoparticle-enhanced charged-particle radiotherapy.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Electron Transport Chains
The ETC is comprised of...
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...

