Raman Spectroscopy identifies differences in ochronotic and non-ochronotic cartilage; a potential novel technique for

A M Taylor1, D D Jenks1, V D Kammath1

  • 1Lancaster Medical School, Faculty of Health & Medicine, Lancaster University, Bailrigg, Lancaster, UK.

Abstract

Related Concept Videos

Electric Potential and Potential Difference01:16

Electric Potential and Potential Difference

Suppose a positive test charge moves away from a positive static charge, then the Coulomb force does positive work, and its electric potential energy decreases. The potential energy per unit charge is defined as the electric potential. The electric potential is independent of the test charge.
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
5.6K
Identifying Statistically Significant Differences: The F-Test01:14

Identifying Statistically Significant Differences: The F-Test

The F-test is used to compare two sample variances to each other or compare the sample variance to the population variance. It is used to decide whether an indeterminate error can explain the difference in their values. The underlying assumptions that allow the use of the F-test include the data set or sets are normally distributed, and the data sets are independent of each other. The test statistic F is calculated by dividing one variance by another. In other words, the square of one standard...
3.3K
Raman Spectroscopy: Overview01:20

Raman Spectroscopy: Overview

The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
1.5K
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
1.1K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.1K
Sum and Difference OpAmps01:22

Sum and Difference OpAmps

Operational amplifiers (op-amps) are versatile devices that extend beyond amplification. In this context, two specific op-amp configurations are explored: the summing and difference amplifiers.
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...
1.4K