Related Experiment Video
Updated: Jan 25, 2026

Longitudinal Follow-Up of Urinary Tract Infections and Their Treatment in Mice using Bioluminescence Imaging
Published on: June 14, 2021
Early versus delayed follow-up after misoprostol treatment for early pregnancy loss
Yossi Mizrachi1, Liliya Tamayev1, Ofer Shemer1
1Department of Obstetrics and Gynecology, the Edith Wolfson Medical Center, 62 Ha-Lokhamim St POB 58100, Holon, Israel(1).
Research Question:
Does extending the follow-up after misoprostol treatment for early pregnancy loss increase the success rate?
Design:
Patients who had experienced early pregnancy loss (<12 weeks) and were treated with misoprostol in a single university-affiliated medical centre were prospectively followed before and after the implementation of a new treatment protocol extending the follow-up from 1 to 2 weeks. All patients received misoprostol 800 μg vaginally on day 1 and a second dose, when needed, on day 4 or 8. Patients underwent surgical aspiration after 1 week in the early follow-up group (n = 84) or 2 weeks in the delayed follow-up group (n = 85) if complete expulsion was not achieved (defined as endometrial thickness ≤15 mm and absence of gestational sac on transvaginal sonography). The primary outcome was treatment success, defined as no need for surgical aspiration.
Results:
Women in the delayed follow-up group had a higher rate of successful treatment compared with women in the early follow-up group (88.2% versus 76.2%, respectively; P = 0.040), and a lower rate of second dose administration (32.9% versus 51.2%, respectively; P = 0.016). The incidence of non-expulsion of the gestational sac was also lower in the delayed follow-up group (1.2% versus 10.7%; P = 0.009). Treatment acceptability did not differ between the study groups.
Conclusion:
In women with early pregnancy loss treated with misoprostol, extending the follow-up protocol from 1 to 2 weeks resulted in an increase in treatment success.
More Related Videos
11:31Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer
Published on: May 20, 2016
07:04A Novel Use of Three-dimensional High-frequency Ultrasonography for Early Pregnancy Characterization in the Mouse
Published on: October 24, 2017
Related Concept Videos
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Adaptations that Reduce Water Loss