Related Experiment Video
Updated: Jan 25, 2026

Use of Rabbit Eyes in Pharmacokinetic Studies of Intraocular Drugs
Published on: July 23, 2016
Correlation between Intraocular Pressure and Angle Configuration Measured by OCT: The Chinese American Eye Study
Benjamin Y Xu1, Bruce Burkemper1, Juan Pablo Lewinger2
1USC Roski Eye Institute, Department of Ophthalmology, Keck School of Medicine at the University of Southern California, Los Angeles, California.
Purpose:
To characterize the relationship between angle configuration measured by anterior segment optical coherence tomography (AS-OCT) and intraocular pressure (IOP).
Design:
Cross-sectional study.
Participants:
Subjects aged 50 years or older were identified from the Chinese American Eye Study (CHES), a population-based epidemiological study in Los Angeles, CA.
Methods:
Each subject underwent a complete ocular exam including Goldmann applanation tonometry, gonioscopy, and AS-OCT imaging. Four AS-OCT images were analyzed per eye and parameters describing angle configuration were measured, including angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), trabecular iris angle (TIA), and scleral spur angle (SSA). The relationship between AS-OCT measurements and IOP was assessed using locally-weighted scatterplot smoothing (LOWESS) regression and change-point analyses.
Main Outcome Measures:
Correlation between AS-OCT measurements and IOP.
Results:
702 eyes (382 closed angle and 320 open angle) from 555 subjects were analyzed. Mean IOP for angle closure eyes was 16.3 ± 3.9 mmHg and open angle eyes was 15.3 ± 2.7 mmHg. Mean IOP increased as AS-OCT measurements decreased for all parameters except TIA750. Once measurement values dropped below parameter-specific threshold values, AS-OCT measurements and IOP were significantly correlated (p < 0.05) for AOD500 (r = -0.416), AOD750 (r = -0.213), ARA500 (r = -0.669), ARA750 (r = -0.680), TISA500 (r = -0.655), TISA750 (r = -0.641), SSA500 (r = -0.538), and SSA750 (r = -0.208). There was no correlation between AS-OCT measurements and IOP in open angle eyes (p > 0.40).
Conclusions:
There is an anatomic threshold for angle configuration below which IOP is strongly related to the degree of angle closure. This finding suggests reconsideration of current definitions of angle closure and may be relevant for developing new OCT-based methods to identify patients at higher risk for elevated IOP and glaucoma.
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Correlations
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Electron Configuration of Multielectron Atoms

