Related Experiment Video
Updated: Jan 25, 2026

Micropatterned Surfaces to Study Hyaluronic Acid Interactions with Cancer Cells
Published on: December 22, 2010
Comparative split-face study of durational changes in hyaluronic acid fillers for mid-face volume augmentation
Kui Y Park1, Jae M Kim1, Joon Seok1
1Department of Dermatology, Chung-Ang University College of Medicine, Seoul, South Korea.
Abstract:
Subsequent changes after injection should be considered when determining the precise volume of injected dermal filler. Several studies have used scoring systems to evaluate facial volumes; however, these scoring systems are not particularly objective. This present study aimed to evaluate the volumetric changes over time on three-dimensional (3D) images and the maintenance potential of various hyaluronic acid (HA) fillers used for mid-face volume augmentation. This split-face clinical study included nine Korean subjects who each received a mid-facial injection of the test filler (B) on one side and a random control filler (J, R, or Y) on the contralateral side. Global, photographic, and 3D scanning assessments were conducted at baseline and after 30 min, 3 days, and 2, 4, 12, and 24 weeks. In all nine cases, the 3D images revealed the largest differences in height where the test filler (B) was injected. The results of subjective scoring systems correlated with the results of 3D imaging. The volumes of monophasic fillers (B and J) were maintained for longer periods of time than those of biphasic fillers (R and Y). The B filler yielded excellent volumizing and spreading effects and good injectability. This filler would be suitable for injection into high-pressure areas, such as the lateral cheek, chin, and nasolabial fold. Moreover, the 3D imaging analysis provided objective and digitized data. The present authors hope that their data will allow physicians to better understand the durational changes in HA fillers and, thus, provide accurate predictions to their patients.
More Related Videos
Related Concept Videos
Additives and Fillers in Concrete
The...
Comparative Excretory Systems
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Mixtures of Acids
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
Constant Volume Calorimetry

