Related Experiment Video
Updated: Jan 25, 2026

Fluorescence Angiography for Evaluation of Aneurysm Perfusion and Parent Artery Patency in Rat and Rabbit Aneurysm Models
Published on: July 24, 2019
Feasibility of Smart Metal Artifact Reduction Algorithm on Computed Tomography Angiography for Clipping of Recurrent
Hideki Kuroda1, Shingo Toyota1, Tetsuya Kumagai1
1Department of Neurosurgery, Kansai Rosai Hospital, Hyogo, Japan.
Background:
The number of patients with a history of clipping of recurrent aneurysms after coil embolization has increased. The aim of this article was to report the feasibility of CT angiography using a commercial metal artifact reduction algorithm (Smart Metal Artifact Reduction [MAR]) for patients who underwent clipping of recurrent aneurysms after coil embolization.
Methods:
Six cases of clipping of recurrent aneurysms after coil embolization were examined with CT angiography using MAR between 2015 and 2018 at a single institution. Conventional CT angiography and three-dimensional digital subtraction angiography data were compared, and depiction of the status of treated aneurysms using MAR was estimated.
Results:
Conventional CT angiography was unable to depict the status of treated aneurysms in the patients with a history of clipping of recurrent aneurysms after coil embolization because of metal artifacts. With MAR, metal artifacts were greatly reduced, and the status of treated aneurysms was able to be depicted, although depiction was inferior to three-dimensional digital subtraction angiography.
Conclusions:
For patients with a history of clipping of recurrent aneurysms after coil embolization, CT angiography using MAR is feasible, although further development of imaging techniques is needed.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Oxidation-Reduction Reactions
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Pulmonary Embolism I: Introduction
Bonding in Metals