Related Experiment Video
Updated: Jan 25, 2026

A Real-time Electrical Impedance Based Technique to Measure Invasion of Endothelial Cell Monolayer by Cancer Cells
Published on: April 1, 2011
New Parylene Coating System with Real-Time and Non-Destructive Electrical Impedance Monitoring of Parylene Layer
Jinsoo Park1, Junsub Kim1, Mu-Hwan Kim2
1Department of Health Science and Technology, GAIHST, Gachon University, Incheon 21999, Republic of Korea.
Abstract:
Parylene is one of the polymers widely used as an electrical insulating or waterproof layer in the fields of semiconductor, electronics, and biomedical engineering owing to its outstanding properties of chemically inertness, biocompatibility, water resistance, low conductivity, and flexibility. It is increasingly required for real-time and non-destructive characterization of the deposition of parylene layer for the quality control and assurance. In the present work, we suggested an impedance measurement based parylene coating system which can provide the electrical properties of the deposited parylene in real-time and non-destructively. For this, the impedance spectra of parylene C, N, or D were measured using the fabricated interdigitated and wave-shaped electrode (IWE) during the chemical vapor deposition (CVD) process. The results showed a feasibility to monitor the impedance change according to the parylene deposition, and that the resistance at the frequency of 2.15 kHz was decreased in dependency on the type of the deposited parylene.
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Non-destructive Tests for Concrete Strength
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Impedance Combination
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...

