Active Accumulation of Spherical Analytes on Plasmonic Hot Spots of Double-Bent Au Strip Arrays by Multiple

Jinhyung Lee1,2, Eun-Ah You3, Do Won Hwang4

  • 1Center for Nano-Bio Measurement, Korea Research Institute of Standards and Science, Daejeon 34113, Korea. jinhyung@kriss.re.kr.

Related Concept Videos

Drug Accumulation During Multiple Dosing: Repetitive IV Injections01:21

Drug Accumulation During Multiple Dosing: Repetitive IV Injections

Calculating drug dosage and accumulation in multiple-dose regimens is crucial for achieving therapeutic efficacy while avoiding toxicity. This involves determining the plasma drug concentrations over time to optimize dosing schedules. The principle of superposition is fundamental in this process, allowing for the prediction of drug concentration in plasma following multiple doses based on single-dose data.The principle of superposition asserts that the plasma concentration-time curves from...
265
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions01:24

Drug Accumulation During Multiple Dosing: Intermittent IV Infusions

Intermittent intravenous (IV) infusion is a method of drug administration where medications are delivered over short infusion periods followed by intervals of no drug delivery. This approach helps to prevent sustained high drug concentrations in the bloodstream, reducing the risk of adverse effects associated with prolonged exposure. Unlike continuous infusion, steady-state concentrations may not be achieved during a single dosing cycle but can be reached through repeated...
240
Spherical Coordinates01:23

Spherical Coordinates

Spherical coordinate systems are preferred over Cartesian, polar, or cylindrical coordinates for systems with spherical symmetry. For example, to describe the surface of a sphere, Cartesian coordinates require all three coordinates. On the other hand, the spherical coordinate system requires only one parameter: the sphere's radius. As a result, the complicated mathematical calculations become simple. Spherical coordinates are used in science and engineering applications like electric and...
15.0K
Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
856
Hot Weather Concreting01:20

Hot Weather Concreting

Concreting at elevated temperatures accelerates the hydration process, leading to quicker setting but potentially reducing the long-term strength of the concrete structure. Additionally, low air humidity fosters rapid moisture loss from the concrete, resulting in reduced workability, pronounced plastic shrinkage, and a higher likelihood of crazing.
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
313
Spherical and Cylindrical Capacitor01:26

Spherical and Cylindrical Capacitor

A spherical capacitor consists of two concentric conducting spherical shells of radii R1 (inner shell) and R2 (outer shell). The shells have  equal and opposite charges of +Q and −Q, respectively. For an isolated conducting spherical capacitor, the radius of the outer shell can be considered to be infinite.
Conventionally, considering the  symmetry, the electric field between the concentric shells of a spherical capacitor is directed radially outward. The magnitude of the field,...
6.7K