Related Experiment Video
Updated: Jan 25, 2026

A New Approach for the Comparative Analysis of Multiprotein Complexes Based on 15N Metabolic Labeling and Quantitative Mass Spectrometry
Published on: March 13, 2014
Comparative reproducibility analysis of 6 intraoral scanners used on complex intracoronal preparations
Ji-Man Park1, Ryan Jin-Young Kim2, Keun-Woo Lee3
1Clinical Associate Professor, Department of Prosthodontics, Yonsei University, College of Dentistry, Seoul, Republic of Korea.
Statement Of Problem:
Although studies have reported the trueness and precision of intraoral scanners (IOSs), studies addressing the accuracy of IOSs in reproducing inlay preparations are lacking.
Purpose:
The purpose of this in vitro study was to compare the accuracy of representative IOSs in obtaining digital scans of inlay preparations and to evaluate whether the IOSs had sufficient depth of field to obtain accurate images of narrow and deep cavity preparations.
Material And Methods:
Digital scans of a bimaxillary typodont with cavity preparations for inlay restorations on the maxillary first premolar, first and second molar, mandibular second premolar, and first molar were obtained using 6 IOSs (CEREC Omnicam, E4D, FastScan, iTero, TRIOS, and Zfx IntraScan). Standard tessellation language (STL) data sets were analyzed using the 3-dimensional analysis software (Geomagic Verify). Color-coded maps were used to compare the magnitude and pattern of general deviation of the IOSs with those of a reference scan. Each tooth prepared for inlay restoration was digitally cut out, and the trueness and precision of each IOS were measured using the superimposition technique. Statistical analyses were conducted using statistical software (α=.05).
Results:
The trueness values were lowest with the FastScan (22.1 μm), followed by TRIOS (22.7 μm), CEREC Omnicam (23.2 μm), iTero (26.8 μm), Zfx IntraScan (36.4 μm), and E4D (46.2 μm). In general, the digital scans of more complicated cavity design showed more deviation. Color-coded maps showed positive vertical discrepancy with the E4D and negative vertical discrepancy with the Zfx IntraScan, especially on the cavity floor. Regarding precision, the highest value was observed in the E4D (37.7 μm), while the lowest value was observed with the TRIOS (7.0 μm). However, no significant difference was found between teeth with different inlay preparations. Scanning errors were more frequently seen in the cervical area.
Conclusions:
Different IOSs and types of cavity design influenced the accuracy of the digital scans. Scans of more complex cavity geometry generally showed higher deviation. The E4D exhibited the most deviation in both trueness and precision, followed by the Zfx IntraScan. The E4D and Zfx IntraScan appeared to have less depth of field than the others to obtain digital scans for inlay preparation with different heights.
More Related Videos
09:34Semi-Automated Planimetric Quantification of Dental Plaque Using an Intraoral Fluorescence Camera
Published on: January 27, 2023
05:51Comparative Analysis of Experimental Methods to Quantify Animal Activity in Caenorhabditis elegans Models of Mitochondrial Disease
Published on: April 4, 2021
Related Concept Videos
Comparing the Survival Analysis of Two or More Groups
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Formation of Complex Ions
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...