Correction to: A new semi-automated workflow for chemical data retrieval and quality checking for modeling

Domenico Gadaleta1, Anna Lombardo2, Cosimo Toma2

  • 1Laboratory of Environmental Chemistry and Toxicology, Department of Environmental Health Sciences, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Via la Masa 19, 20156, Milan, Italy. domenico.gadaleta@marionegri.it.

Related Concept Videos

Protein Folding Quality Check in the RER01:29

Protein Folding Quality Check in the RER

ER is the primary site for the maturation and folding of soluble and transmembrane secretory proteins. The calnexin cycle is a specific chaperone system that folds and assesses the confirmation of N-glycosylated proteins before they can exit the ER lumen. The primary players of this quality check pipeline are the lectins, ER-resident chaperones, and a glucosyl transferase enzyme. In case the calnexin system in the lumen fails to salvage a misfolded protein, it is transported to the cytoplasm...
5.1K
Retrieval01:12

Retrieval

Retrieval is the process of getting information out of memory storage and back into conscious awareness. This ability is essential for daily tasks like brushing hair and teeth, driving to work, and performing job duties. Retrieval occurs in three ways: recall, recognition, and relearning.
Recall involves accessing information without cues, such as during an essay test, where individuals must retrieve facts and concepts from memory unaided. Another example is remembering the name of a colleague...
427
Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
285
ER Retrieval Pathway01:45

ER Retrieval Pathway

In the secretory pathway, vesicles transport proteins from one cellular compartment to another in forward transport to deliver the protein to its correct location. Occasionally, misfolded proteins and incorrect proteins escape their original compartments, and a retrieval pathway is used to return the escaped proteins to their original compartment.
The ER uses many checkpoints to prevent the entry of incorrectly folded or a resident protein as cargo onto a transport vesicle. These mechanisms...
4.7K
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
515
Chemical Formulas02:52

Chemical Formulas

A chemical formula presents information about the proportions of atoms constituting a particular chemical compound or molecule, mainly using symbols of elements and numbers. At times other symbols, such as dashes, parentheses, brackets, commas, plus, and minus signs, are also used. A chemical formula can be one of three types – molecular, empirical, and structural.
61.1K