Related Experiment Video
Updated: Jan 25, 2026

Echocardiographic Measurement of Right Ventricular Diastolic Parameters in Mouse
Published on: April 27, 2019
A Novel Mathematical Model for Correcting the Physiologic Variance of Two-Dimensional Echocardiographic Measurements
Gui-Hua Yao1, Xiang-Yun Chen1, Qing Zhang1
1Department of Cardiology, Qilu Hospital of Shandong University (Qingdao), Qingdao, China.
Background:
To facilitate differentiation between normal and abnormal values, it is necessary to correct echocardiographic measurements for physiologic variance induced by age, gender, and body size variables.
Methods:
A total of 34 two-dimensional echocardiographic parameters were measured in 1,224 healthy Chinese adults with body mass index < 25.0 kg/m2. An optimized multivariate allometric model and scaling equations were first developed in 858 subjects (group A), and their reliability was then verified in the remaining 366 subjects (group B). The traditional single-variable isometric model in which parameters are linearly corrected by a single body size variable (height, weight, body mass index, or body surface area) was used for comparison. The success of correction was defined as the absence of significant correlations (r > 0.20, P < .05) between the corrected values and age or any body size variables, while maintaining high correlations (r > 0.80) between the corrected and uncorrected values.
Results:
Before correction, all 34 parameters correlated significantly with one or more of the physiologic variables of age and body size and differed significantly between men and women on 29 parameters (85.3%) in both groups. The success rate of correction with the single-variable isometric model was only 11.0% (15 of 136 corrections due to four variable corrections used for each parameter), while use of the optimized multivariate allometric model successfully corrected all 34 parameters (100%) for physiologic variance induced by age and body size variables and eliminated the gender differences in 32 parameters (94.1%). A new set of reference values for corrected echocardiographic measurements independent of age, gender, and body size variables were established.
Conclusions:
The novel optimized multivariate allometric model developed in this study is superior to traditional the single-variable isometric model in the correction of echocardiographic parameters for physiologic effects of age, gender, and body size variables and thus should be encouraged in both scientific research and clinical practice.
Related Concept Videos
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Variance
The standard deviation measures the spread in the same units as the data....
Clearance Models: Physiological Models
The organ's clearance rate depends on the blood flow to the organ and the extraction ratio (E). The extraction ratio describes the organ's...
Distance Corrections
Fundamental Mathematical Principles in Pharmacokinetics: Mathematical Expressions and Units
One significant application of mathematics in pharmacokinetics is the characterization of drug distribution through the volume of distribution...
Power Factor Correction

