Related Experiment Video
Updated: Jan 25, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Minimally invasive stabilization for thoracolumbar and lumbar fractures: a comparative study with short segment open
Yu Chao Lee1, Michael Selby1, Mario Zotti1
1Spinal Injuries Unit, Royal Adelaide Hospital, Adelaide, Australia.
Background:
Analysis was performed of two patient cohorts who underwent fixation without fusion for unstable thoracolumbar and lumbar fractures: (I) minimally invasive surgery (MIS) group using combined monoaxial-polyaxial pedicle screws inserted percutaneously; (II) open surgery (OS) group using Schanz screw constructs. Our aim was to compare radiographic and clinical indices of the 'gold standard' of open Schanz screw to MIS monoaxial-polyaxial screw constructs.
Methods:
There were 13 patients in the MIS group and 19 in the OS group. Primary outcomes were the correction of fracture angulation and percentage loss of reduction until fracture union. Patient demographics, fracture classification, perioperative data and complications were also collected.
Results:
There was no significant difference in cohorts when comparing demographics and fracture classification. Operative time was 50 minutes less and haemoglobin drop was 9 g/L less in the MIS group. Radiation exposure was significantly higher in the MIS group. Pre-operatively, the mean kyphotic angle was 22° in the MIS and 16° in the OS group. Both groups achieved similar on-table correction. On immediate postoperative erect radiographs, the MIS group lost 15% of correction vs. 55% in the OS group. At final follow-up, both groups had a further loss of position, but significantly higher in the OS group (28% vs. 96%).
Conclusions:
Combined polyaxial-monoaxial screw MIS constructs demonstrate favorable radiological and clinical outcomes for treatment of unstable thoracolumbar and lumbar fractures. Our study also demonstrates higher rates of radiological collapse in the OS cohort.
Related Concept Videos
RNA Stability
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Nuclear Stability
To hold positively charged protons together...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
mRNA Stability and Gene Expression
Cis-acting Elements involved in mRNA stability