Related Experiment Video
Updated: Jan 25, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Predictors of Extended Postoperative Length of Stay After Uncomplicated Transcatheter Aortic Valve Replacement
Alexis K Okoh1, Setri Fugar, Nathan Kang
1Cardiovascular Research Unit, RWJ Barnabas Health Heart Centers, Newark Beth Israel Medical Center, 201 Lyons Avenue, Suite G5, Newark, NJ 07112 USA. disciple951@gmail.com.
Background:
The current study aims to identify predictors of extended postoperative length of stay (PLOS) after uncomplicated transcatheter aortic valve replacement (TAVR).
Methods:
Patients who underwent TAVR at a single center between June 2012 and June 2016 were analyzed. Patients were stratified by time into an early cohort (EC; 2012-2014) and current cohort (CC; 2015-2016). Those who had complications post procedure were excluded. The CC group was dichotomized based on its median PLOS. Factors associated with a longer PLOS were investigated by using multivariable logistic regression analysis.
Results:
Mean age of the 686 patients (299 in the EC group and 387 in the CC group) was 82 ± 8 years. PLOS in the CC group was significantly lower than in the EC group (4 days vs 6 days, respectively; P<.001). Median PLOS in the CC group was 2 days. Dichotomizing the CC group by median PLOS resulted in 148 patients (54%) ≤2 days vs 128 patients (46%) >2 days. Of these, PLOS was 1 day in 71 patients (26%) and 2 days in 61 patients (28%). Independent predictors of PLOS >2 days were non-transfemoral approach, non-elective admission, female sex, low mean transaortic gradient, presence of chronic renal failure, and pulmonary hypertension.
Conclusion:
Experience coupled with improvements in TAVR technology over the past few years have led to a significant decrease in PLOS after TAVR. In the current TAVR era, 1 out of every 2 patients stays for a day or two in the absence of perioperative adverse events.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Continuous Renal Replacement Therapy
Gravitational Potential Energy for Extended Objects
Peripheral Artery Disease V: Postoperative Nursing Management
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation I: Introduction