A Hydrophilic-Wire Induced Vascular Perforation Causing Mediastinal Hematoma During Transradial Coronary Intervention

Jincheng Guo1, Jiahui Song

  • 1Department of Cardiology, Luhe Hospital, Capital Medical University, Tongzhou District, Beijing, China 101149. guojcmd@126.com.

Related Concept Videos

Esophageal Perforation-I: Introduction01:22

Esophageal Perforation-I: Introduction

Esophageal perforation is a severe medical condition characterized by a breach in the integrity of the esophageal wall. This breach can occur due to various factors such as trauma, medical procedures, or underlying diseases. When the esophageal wall is compromised, it allows food, fluids, and digestive juices into the chest cavity or adjacent structures, leading to potential complications and health risks.
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
543
Nursing Interventions I: Taxonomy of Nursing Interventions01:03

Nursing Interventions I: Taxonomy of Nursing Interventions

Nursing interventions are chosen as part of the planning process to achieve patient outcomes. Once nursing diagnoses are determined, the goals and outcomes are specified, then the nursing interventions are selected and individualized according to the patient's situation.
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
3.7K
Nursing Interventions II: Selecting and Classifying the Nursing Interventions01:29

Nursing Interventions II: Selecting and Classifying the Nursing Interventions

Creating and executing a nursing diagnosis helps nurses plan care and guide patient, family, and community interventions. They are developed based on a patient's physical evaluation and support measuring the outcomes. It is not recommended to select random interventions throughout the planning process. Instead, consider the following six essential factors when choosing interventions:
3.1K
Household Wiring And Electrical Safety01:13

Household Wiring And Electrical Safety

Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.6K
Magnetic Field Due To A Thin Straight Wire01:28

Magnetic Field Due To A Thin Straight Wire

Consider an infinitely long straight wire carrying a current I. The magnetic field at point P at a distance a from the origin can be calculated using the Biot-Savart law.
6.1K
Magnetic Field Due to Two Straight Wires01:18

Magnetic Field Due to Two Straight Wires

Consider two parallel straight wires carrying a current of 10 A and 20 A in the same direction and separated by a distance of 20 cm. Calculate the magnetic field at a point "P2", midway between the wires. Also, evaluate the magnetic field when the direction of the current is reversed in the second wire.
4.6K