Inductively coupled plasma mass spectrometry assay for quantification of free infliximab in serum
Igor Y Pavlov1, Rebecca L Parker1, Eszter Lázár-Molnár1
1ARUP Laboratories, Department of Pathology, University of Utah School of Medicine, Salt Lake City, UT, United States of America.
TNF antagonists such as infliximab are effective for the treatment of several inflammatory and autoimmune diseases. Recent clinical studies have advocated the importance of measuring trough infliximab levels to guide treatment decisions. We have developed a novel assay for measuring serum free infliximab levels using inductively coupled plasma-mass spectrometry (ICP-MS). The method involves the incubation of patient serum in wells coated with recombinant TNF, followed by detection with lanthanide-labeled monoclonal anti-human IgG1 and ICP-MS analysis. Full method validation was performed and results for clinical samples tested with the new method were compared with those obtained from a capture ELISA and a cell-based assay. Validation of the ICP-MS assay revealed a lower limit of detection of 0.4 μg/mL in serum. The linear range of quantitation was 1-50 μg/mL. The within-run and between-run precision had a coefficient of variation (CV) of <10%, and the accuracy of the assay had a CV of <15%. In serum samples, the ICP-MS method was devoid of analytical interferences by high levels of hemoglobin, bilirubin and triglycerides. Serum sample results from 123 drug-naïve donors revealed a test cutoff at 0.5 μg/mL. Test results from clinical samples obtained by the ICP-MS method showed strong correlation with both the ELISA and cell-based assay. The ICP-MS methodology presented in this study is a robust method for measuring TNF antagonist serum levels, which makes it well suited for therapeutic drug monitoring in the clinical laboratory.
TNF antagonists such as infliximab are effective for the treatment of several inflammatory and autoimmune diseases. Recent clinical studies have advocated the importance of measuring trough infliximab levels to guide treatment decisions. We have developed a novel assay for measuring serum free infliximab levels using inductively coupled plasma-mass spectrometry (ICP-MS). The method involves the incubation of patient serum in wells coated with recombinant TNF, followed by detection with lanthanide-labeled monoclonal anti-human IgG1 and ICP-MS analysis. Full method validation was performed and results for clinical samples tested with the new method were compared with those obtained from a capture ELISA and a cell-based assay. Validation of the ICP-MS assay revealed a lower limit of detection of 0.4 μg/mL in serum. The linear range of quantitation was 1-50 μg/mL. The within-run and between-run precision had a coefficient of variation (CV) of <10%, and the accuracy of the assay had a CV of <15%. In serum samples, the ICP-MS method was devoid of analytical interferences by high levels of hemoglobin, bilirubin and triglycerides. Serum sample results from 123 drug-naïve donors revealed a test cutoff at 0.5 μg/mL. Test results from clinical samples obtained by the ICP-MS method showed strong correlation with both the ELISA and cell-based assay. The ICP-MS methodology presented in this study is a robust method for measuring TNF antagonist serum levels, which makes it well suited for therapeutic drug monitoring in the clinical laboratory.
More Related Videos
09:05Imaging Metals in Brain Tissue by Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry LA-ICP-MS
Published on: January 22, 2017
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Tandem Mass Spectrometry
Mass Spectrometry: Overview