Related Experiment Video
Updated: Jan 25, 2026

Calibration of Vector Network Analyzer for Measurements in Radio Frequency Propagation Channels
Published on: June 2, 2020
CC-DTW: An Accurate Indoor Fingerprinting Localization Using Calibrated Channel State Information and Modified
Zhongliang Deng1, Xiao Fu2, Qianqian Cheng3
1School of Electronic Engineering, Beijing University of Posts and Telecommunications, Beijing 100876, China. dengzhl@bupt.edu.cn.
Abstract:
Indoor wireless local area network (WLAN) based positioning technologies have boomed recently because of the huge demands of indoor location-based services (ILBS) and the wide deployment of commercial Wi-Fi devices. Channel state information (CSI) extracted from Wi-Fi signals could be calibrated and utilized as a fine-grained positioning feature for indoor fingerprinting localization. One of the main factors that would restrict the positioning accuracy of fingerprinting systems is the spatial resolution of fingerprints (SRF). This paper mainly focuses on the improvement of SRF for indoor CSI-based positioning and a calibrated CSI feature (CCF) with high SRF is established based on the preprocess of both measured amplitude and phase. In addition, a similarity calculation metric for the proposed CCF is designed based on modified dynamic time warping (MDTW). An indoor fingerprinting method based on CCF and MDTW, named CC-DTW, is then proposed to improve the positioning accuracy in indoors. Experiments are conducted in two indoor office testbeds, and the performances of the proposed CC-DTW, one time-reversal (TR) based approach and one Euclidean distance (ED) based approach are evaluated and discussed. The results show that the SRF of CC-DTW outperforms the TR-based one and the ED-based one in both two testbeds in terms of the receiver operating characteristic (ROC) curve metric, and the area under curve (AUC) metric.
More Related Videos
06:33Three-dimensional Imaging of Bacterial Cells for Accurate Cellular Representations and Precise Protein Localization
Published on: October 29, 2019
10:45Analysis of Actomyosin Dynamics at Local Cellular and Tissue Scales Using Time-lapse Movies of Cultured Drosophila Egg Chambers
Published on: June 3, 2019
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
IR Frequency Region: Fingerprint Region
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
Plotting and Calibrating the Root Locus
The maximum gain occurs at the breakaway points between open-loop poles on the real axis, while the minimum gain is...
Calibration Curves: Correlation Coefficient