Alemtuzumab Induction Versus Conventional Immunosuppression in Heart Transplant Recipients

Stormi E Gale1, Bharath Ravichandran2, Van-Khue Ton3

  • 11 Department of Pharmacy Practice and Science, University of Maryland School of Pharmacy, Baltimore, MD, USA.

The use of alemtuzumab for induction therapy in orthotopic heart transplantation remains controversial, despite its observed benefits in other transplant populations. This study aimed to evaluate whether alemtuzumab conferred a lower risk of rejection while reducing toxicities commonly attributed to standard immunosuppression in orthotopic heart transplantation. We included adult patients who underwent orthotopic heart transplantation and received induction therapy with alemtuzumab (n = 26) or standard immunosuppression (n = 26). The primary end point was freedom from grade ≥2 rejection at 12 months. Baseline characteristics were similar between the groups with the exception of poorer renal function in the alemtuzumab group (P < .05). The primary end point of freedom from grade ≥2 rejection at 12 months was not different between alemtuzumab and standard therapy (76.9% vs 96.2%, P = .077), likely due to similarities in the rates of antibody-mediated rejection in the 2 groups. However, grade ≥2 acute cellular rejection was considerably lower with alemtuzumab (0% vs 19.2%, P = .02), as was acute cellular rejection of any severity (50% vs 7.7%, P = .004). Deterioration in renal function was significantly greater among patients receiving standard therapy as evidenced by decreases in glomerular filtration rate (-25.6 vs -9.2 mL/min, P = .032). No differences in hematologic or infectious complications were observed. In conclusion, alemtuzumab reduced several important rejection-related outcomes while ameliorating the toxicities associated with standard immunosuppression therapy, making it a promising agent for induction in orthotopic heart transplantation.

Related Concept Videos

Sign Convention01:30

Sign Convention

When analyzing a beam subjected to various loads, it is crucial to understand the internal forces and moments generated within the structure. These internal forces can be broadly classified into normal forces, shear forces, and bending moments. To determine these forces and moments, we use the method of sections and apply a specific sign convention based on their direction and the side of the section being analyzed.
The normal force acts perpendicular to the beam's cross-section and can...
3.4K
Enolate Mechanism Conventions01:15

Enolate Mechanism Conventions

When a carbonyl compound is treated with a strong base, the α position gets deprotonated to give a resonance-stabilized intermediate called an enolate. Enolates are ambident nucleophiles because they possess two nucleophilic sites that can attack an electrophile owing to the delocalization of the negative charge between the α carbon and oxygen atoms. When the oxygen atom attacks an electrophile, it is called O-attack, whereas electrophilic attack via the α carbon is known as...
2.8K
Anatomy of the Heart01:27

Anatomy of the Heart

The human heart is made up of three layers of tissue that are surrounded by the pericardium, a membrane that protects and confines the heart. The outermost layer, closest to the pericardium, is the epicardium. The pericardial cavity separates the pericardium from the epicardium. Beneath the epicardium is the myocardium, the middle layer, and the endocardium, the innermost layer. There are four chambers of the heart: the right atrium, the right ventricle, the left atrium, and the left ventricle.
119.5K
Induction01:16

Induction

An emf is induced when the magnetic field in a coil is changed by pushing a bar magnet into or out of the coil. emfs of opposite signs are produced by motion in opposite directions, and the directions of emfs are also reversed by reversing poles. The same results are produced if the coil is moved rather than the magnet—it is the relative motion that is important. The faster the motion, the greater the emf. Additionally, there is no emf when the magnet is stationary relative to the coil.
A...
5.6K
Self-Inductance01:24

Self-Inductance

Mutual inductance arises when a current in one circuit produces a changing magnetic field that induces an emf in another circuit. On the other hand, self-inductance arises when the current passing through the circuit changes, creating a changing magnetic flux, resulting in inductance in the same circuit.
Consider a circuit connected to an AC source. As the current varies with time, the magnetic flux through the circuit correspondingly changes. Faraday's law tells us that an emf would...
3.0K
Inductive Reasoning00:59

Inductive Reasoning

Inductive reasoning is a form of logical thinking that uses related observations to arrive at a general conclusion. It is uncertain and operates in degrees to which the conclusions are credible. As such, inductive arguments can be weak or strong, rather than valid or invalid, and conclusions can be used to formulate testable, falsifiable hypotheses.
Inductive reasoning is common in descriptive science. A life scientist makes observations and records them. This data can be qualitative or...
65.9K