Enhanced output performance on LbL multilayer PVDF-TrFE piezoelectric films for charging supercapacitor
Moon Hyun Chung1,2, Seunghwan Yoo1,2, Hyun-Jun Kim1
1Energy ICT·ESS Laboratory, Energy Efficiency Technologies and Materials Science Division, Korea Institute of Energy Research, 152 Gajeong-ro, Yuseong-gu, Daejeon, 34129, Republic of Korea.
Abstract:
The piezoelectric nanogenerator (PENG) has the potential to become a promising power supply for monitoring and sensors in Internet of Things (IoT) systems through wireless networks. In order to further increase the utilization of energy harvesters in an IoT system, we introduce a novel approach that greatly enhances the piezoelectric output performances by employing the layer-by-layer (LbL) method. Poly(vinylidenefluoride-co-trifluoroethylene) (PVDF-TrFE) polymer film, which has piezoelectric properties and mechanical flexibility, was used for the active layer in PENG. The maximum open-circuit voltage and closed-circuit current of the LbL multilayer PENG reached 34 V and 100 nA, respectively. In particular, the closed-circuit current of the LbL multilayer PENG was dramatically improved to be five times higher than that of the single-layer PENG. Furthermore, a supercapacitor was employed to investigate the energy storage capability of PENGs using different methods. The proposed LbL multilayer PENG is expected to be a candidate for a promising power supply for self-powered systems in the IoT system.
Related Concept Videos
Formal Charges
Ions and Ionic Charges
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Atomic Radii and Effective Nuclear Charge
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...