Paper and electronic versions of HM-PRO, a novel patient-reported outcome measure for hematology: an equivalence

Pushpendra Goswami1, Esther N Oliva2, Tatyana Ionova3

  • 1School of Life & Medical Sciences, University of Hertfordshire, Hatfield, UK.

Aim: To determine measurement equivalence of paper and electronic application of the hematological malignancy-patient-reported outcome (HM-PRO), a specific measure for the evaluation of patient-reported outcomes in HMs. Patients & methods: Following International Society of Pharmacoeconomics and Outcomes Research ePRO Good Research Practice Task Force guidelines, a total of 193 adult patients with different HMs were recruited into a multicenter prospective study. The paper and the electronic version of the instrument were completed in the outpatient clinics in a randomized crossover design with a 30 min time interval to minimize the learning effect. Those who completed the paper version first, completed the electronic version after 30 min and vice versa. Instrument version and order effects were tested on total score of the two parts of the HM-PRO (Part A: quality of life and Part B: signs & symptoms) in a two-way ANOVA with patients as random effects. Intraclass correlation coefficients (95% CI) and Spearman's rank correlation coefficients were used to evaluate test-retest reliability and reproducibility. The effects of instrument version and order were tested on total score of the two parts of HM-PRO. Results: The questionnaire version and administration order effects were not significant at the 5% level. There were no interactions found between these two factors for HM-PRO (Part A [quality of life]; p = 0.95); and (part B [signs and symptoms]; p = 0.72]. Spearman's rank correlation coefficients were greater than 0.9, and intraclass correlation coefficients ranged from 0.94 to 0.98; furthermore, the scores were not statistically different between the two versions, showing acceptable reliability indexes. Noteworthy, the difference between the completion time for both paper (mean = 6:38 min) and electronic version (mean = 7:29 min) was not statistically significant (n = 100; p = 0.11). Patients did not report any difficulty in completing the electronic version during cognitive interviews and were able to understand and respond spontaneously. Conclusion: Measurement equivalence has been demonstrated for the paper and electronic application of the HM-PRO.

Related Concept Videos

Data Reporting and Recording01:24

Data Reporting and Recording

Reporting and recording are crucial in data documentation. The timely, thorough, and accurate documentation of facts is essential when recording patient data. Failure to record findings during an assessment or interpretation of a problem will result in loss of information and make the patient document unreliable. The reader is left with general impressions if the information is not specific. A recording is documenting data of the individual's health information in a traceable, secure, and...
5.4K
Pharmaceutical Equivalents01:26

Pharmaceutical Equivalents

As defined by regulatory standards, pharmaceutical equivalents require generic drug products to have identical dosage forms and chemically identical active pharmaceutical ingredients (APIs). They must adhere to compendial or applicable standards for potency, content uniformity, disintegration times, and dissolution rates. In the case of modified-release dosage forms, variations in drug content are permissible as long as the delivered amount remains consistent with the innovator drug product.
192
Equivalent Capacitance01:19

Equivalent Capacitance

Multiple capacitors can be connected in a circuit in series or parallel configuration. When the capacitor combination is connected to a battery, the potential drop across each capacitor and the magnitude of charge stored in the individual capacitor depends on the type of the connection. The capacitor combination is replaced by a single equivalent capacitor that stores the same amount of charge as the combination for a given potential difference.
The following strategies are adopted to calculate...
2.1K
Equivalent Capacitance01:19

Equivalent Capacitance

From the study of resistive circuits, it is understood that employing a series-parallel combination serves as an effective strategy for simplifying circuits. Capacitors can be arranged within a circuit in one of two ways: a series configuration or a parallel configuration. The way these capacitors are connected to a battery will influence both the potential drop across each individual capacitor and the size of the charge that each capacitor can store. This is determined by the specific type of...
686
Th&#233venin Equivalent Circuits01:18

Thévenin Equivalent Circuits

The household power distribution system, encompassing distribution lines and transformers, serves as the primary network. Electrical appliances within a household can be represented as load impedance. To simplify this intricate distribution system, Thévenin's theorem can be applied to create a Thévenin equivalent circuit. If an AC circuit is partitioned into two parts (circuit A and circuit B), connected by a single pair of terminals as shown in Figure 1.
660
Equivalent Resistance01:16

Equivalent Resistance

In circuit analysis, situations often arise where resistors are neither in series nor parallel configurations. To tackle such scenarios, three-terminal equivalent networks like the wye (Y) (Figure 1 (a)) or tee (T) and delta (Δ) (Figure 1 (b)) or pi (π) networks come into play. These networks offer versatile solutions and are frequently encountered in various applications, including three-phase electrical systems, electrical filters, and matching networks.
951