Related Experiment Video
Updated: Jan 25, 2026

Visualization of Pseudomonas aeruginosa within the Sputum of Cystic Fibrosis Patients
Published on: July 16, 2020
Optimising fluorescein diacetate sputum smear microscopy for assessing patients with pulmonary tuberculosis
Sumona Datta1,2,3, Keren Alvarado2, Robert H Gilman4
1Infectious Diseases & Immunity, Wellcome Trust Centre for Global Health Research, Imperial College London, United Kingdom.
Background:
Assessing Mycobacterium tuberculosis (TB) viability by fluorescein diacetate (FDA) microscopy can predict TB culture results, treatment response and infectiousness. However, diverse methods have been published. We aimed to optimise FDA microscopy, minimising sputum processing, biohazard and complexity for use in resource-constrained settings.
Methods And Results:
Optimization: Patients with smear-positive pulmonary TB before treatment and healthy control participants provided sputa. These were divided into equal aliquots that were tested directly or after NaOH centrifuge-decontamination. Each aliquot was cultured and used to prepare slides (n = 80). FDA microscopy used: 1 or 3 drops of sputum; with/out acid-alcohol wash; with/out phenol sterilization; with 0/30/60 seconds KMnO4 quenching. Control samples all had negative culture and microscopy results. FDA microscopy had higher sensitivity when performed directly (without centrifuge-decontamination) on 1 drop of sputum (P<0.001), because 3 drops obscured microscopy. Acid-alcohol wash and KMnO4 quenching made bacilli easier to identity (P = 0.005). Phenol sterilization did not impair microscopy (P>0.1). Validation: The 2 protocols that performed best in the optimization experiments were reassessed operationally by comparing duplicate slides (n = 412) stained with KMnO4 quenching for 30 versus 60 seconds. FDA microscopy results were similar (P = 0.4) and highly reproducible, with 97% of counts agreeing within +/-1 logarithm. Storage: Smear microscopy slides and aliquots of the sputum from which they were made were stored for 4 weeks. Twice-weekly, paired slides (n = 80) were stained with freshly prepared versus stored FDA and read quantitatively. Storing sputum, microscopy slides or FDA solution at 4°C or room temperature had no effect on FDA microscopy results (all P>0.2). Cost: Material costs for each slide tested by FDA microscopy using reagents purchased locally were USD $0.05 and required the same equipment, time and skills as auramine acid-fast microscopy.
Conclusions:
We recommend a simple, bio-secure protocol for FDA microscopy that provides sensitive and repeatable results without requiring centrifugation.
More Related Videos
Related Concept Videos
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
Pulmonary Tuberculosis II
Here is a detailed explanation of its pathophysiology:
Transmission: The process begins when a person inhales droplet nuclei containing M. tuberculosis. These are typically released into the air when an individual with pulmonary or...
Pulmonary Tuberculosis V
Latent tuberculosis infection occurs when TB bacteria are present in a person's body, but are not causing illness or symptoms. It is not contagious, and preventive treatment is crucial to avoid the...
Sputum Studies I: Gram Stain, cytology, and Acid-fast smear and culture
Gram Stain
The Gram Stain is an integral part of sputum studies. It involves the staining of sputum, which permits...
Pulmonary Tuberculosis III
The first classification is based on the development of the disease, and it includes the following categories:
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...

